L-Series and FCS-18 Graphical User Interface User Manual
7.2.4 Voltage sweep transient
Voltage sweep transients will cause the output voltage to change
gradually from the Goto V value to the Final V value over a period of time
specified by the Delay field. The delay value can range from 1 ms to 9999
seconds. At the end of the delay period, the output value will remain at the
value specified by the Final V field.
Note that if the Final V value is set to the same value as the Goto V value,
the V Sweep transient effectively becomes a V Step transient.
The illustration shown here reflects an example of a typical V Sweep
transient. The required row in the data entry screen for this transient would
be as shown below. In this case, register 0 was used to store the transient
information.
Rev D – March 2011
California Instruments
55
Voltage Sweep transient from 135 V rms to 30 V rms for a duration of 120 ms. End
value is 30 Vrms. (Final V)
120 ms
135 Vrms
30 Vrms