L-Series and FCS-18- Graphical User Interface User Manual
46
California Instruments
Rev D – March 2011
6.9.3 Phase angle control
Phase angles can be set for each phase individually. Note that setting the
phase angle for phase A with an internal clock reference has no effect as
phase A will be used as the reference. Phase angle for phase A is only
meaningful if external sync is used. External sync is not supported by the
LSGUI program at this time.
6.9.4 Waveform type selection
Based on the connected L-Series configuration, different types of
waveforms can be selected for each of three phases. The relevant controls
will be available to the user if the waveform options are supported by the
connected L-Series unit. Specifically, the following configurations are
required to support the different waveforms :
Sine
Supported by all L-Series AC sources
Clipped
Only available with -PT type controller. Creates sine waveforms
with total harmonic distortion ranging from 0 to 20 %
Square
Only available if Square wave option is installed in the L-Series
unit. See the System Settings screen for information on
installed options. (Refer to section 5.2)
Содержание 12000L
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 6: ...ii This page intentionally left blank ...