Section 2
Page 2 - 7
Fixed Thermal Imaging System
Installation Guide
150.0 (5.9")
175.0 (6.9")
102.5 (4.04")
22.3 (0.88")
Ø62.0 (2.45")
175.0 (6.89")
201.3 (7.9")
17.8 (0.7")
VIEW SHOWING COVER REMOVED FROM RUGGED HOUSING
CONNECT
CABLE
TO
THIS CONNECT
OR ON IMAGER
NOTE
ALIGN RED DOTS FOR CORRECT
ORIENT
ATION
FIT
IMAGER LENS BODY
INT
O THIS
BORE
SECURE IMAGER
TO RUGGED HOUSING USING
THESE 2 CLAMPS
ADJUST
AS
NECESSAR
Y
EXTEND
APPROXIMA
TEL
Y 250mm (10")
OF CABLE INCLUDING CONNECT
OR
THROUGH THE
CABLE
CLIP
BEFORE CLAMPING
TO
ADJUST
ETHERNET
IP
ADDRESS, OPEN COVER
AND ROT
ATE SWITCH.
IP
ADDRESS = 10.1.10.10X WHERE X = ROT
AR
Y SWITCH POSITION.
(F
ACT
OR
Y DELIVERED
ADDRESS = 10.1.10.102 POSITION 0 IS FOR DHCP
ONL
Y)
Fig. 6
FTI
-E
Ca
mer
a Installation
D
imensions