Appendix A
Page 3
Fixed Thermal Imaging System
Installation Guide
A2 Slag Detection System Specifications
Observable temperature range: 400 to 2000°C/752 to 3632°F
(based on blackbody temperature)
Frame frequency:
30 Hz
Focusing range:
4m/13.1ft to infinity
Temperature resolution:
0.5°C (for 600°C blackbody)
Field of view:
7.5° (horizontal) x 5.5° (vertical)
Image pixels:
384 x 288
Detector:
Amorphous silicon FPA
Sealing:
To IP65
A2.1 Slag Detection Measurement Function
Measuring area:
Adjustable over scene
Measurable temperature range: 600 to 2000°C/1472 to 3632°F
Display resolution:
1°C
Accuracy:
±1% absolute temperature (K)