STRATOS VERTICAL PLATFORM LIFTS:
Install Manual
04DEC2020 | 630-00147 REV A
31
TROUBLESHOOTING
STRATOS: SECTION 6
BRAKE MOMENTARY SWITCH
The brake on the back of the gear motor is 24V
DC “fail safe,” electromagnetic holding brake. The
brake is released when 24V DC is applied. Pressing
the BRAKE momentary switch will apply 24V DC and
release the brake with an audible “Click.”
This switch can be used to check brake operation
and is recommended to be used in the emergency
lowering procedure.
RESET MOMENTARY SWITCH
Pressing the RESET momentary switch will reset the
processor and exit “Service Mode” if board were
in that mode. “Out of Service Mode” flag is not
cleared by pressing the RESET switch.
The control board has three (3) momentary switches and three (3) permanent cuttable switches/jumpers.
See Figure 6-5.
Figure 6-5
Service
Momentary Switch
Brake Momentary
Switch
Reset Momentary
Switch
3X Permanent
Cuttable Switches
Pressing and holding this switch could result in the
platform slowly drifting down.
WARNING
!