18 //
24
P/N: 630-00047 RevB 11519
Hercules II 600 Vertical Platform Lift Install Manual | www.Ameriglide.com | 866-378-6648
In case of power failure, this lift is equipped with a Manual Override Crank that permits it to be
raised or lowered by hand. Before using, check to ensure that the manual system is required.
Verify the Need for Manual Override
Before using the Manual Override Crank, try trouble-shooting by verifying the following:
•
Check that the Emergency Stop Switch is pulled out.
•
Check that the electrical cord is plugged into the wall.
•
Check that the building’s circuit breaker has not tripped.
•
Try to run the lift by pushing both the up and down buttons.
MANUAL OVERRIDE PROCEDURE
If, after Troubleshooting as above, the lift still will not run, complete the following steps:
Step 1: Unplug the lift from the wall. Push in the Emergency Stop Button.
Step 2: Loosen the screws and remove the top cap at the top of the tower.
Step 3: Insert the manual hand crank onto the upper nut on the top of the drive screw.
Rotate the crank to raise or lower the platform.
For your safety and that of the end-user, if you have any questions about installation or service
MANUAL OVERRIDE
Warning
Do not service or operate the Manual Override Crank while the lift
is connected to electricity.
Warning
Never operate the lift while the Manual Override Crank is inserted
into the lift.
Содержание AMGHERC600-4
Страница 24: ...P N 630 00047 RevB 11519 ...