12 //
24
P/N: 630-00047 RevB 11519
Hercules II 600 Vertical Platform Lift Install Manual | www.Ameriglide.com | 866-378-6648
TOP LANDING GATE (OPTIONAL)
The optional top landing gate is provided
with a combination mechanical lock and
electric contact (interlock).
The interlock:
•
Prevents the lift from running if the
gate is not closed.
•
Prevents the gate from being opened
if the platform is not at the top
landing.
•
Unlocks when the lift is on the upper
limit switch.
A crescent shaped key is provided
to manually unlock the gate during
installation. The key is inserted from the
back side to lift up on the solenoid that
holds the gated locked.
Mount the gate by placing onto the upper
landing making sure to align the gate
opening with the platform (outer guard
rail not shown for clearity). There are a
number of attachment holes provided in the
threshold portion of the gate for mounting
using wood lag screws or concrete anchors
as appropriate.
Remove the latch post cover and connect
the call-send and interlock wire harnesses.
The vertical posts of the gate must be
attached to a supporting structure, (the
gate is not designed to be freestanding).
A length of multi‐conductor wire will need
to be ran from the bottom of the lift tower
up to the landing gate. Consult local codes
for type and mounting requirements. After
wiring is completed, the wiring harness
must be plugged into it appropriate
receptacle on the controller (ref pg. 9).
Wiring Connections
EMI Gate Harness
Gate Harness
Black
Orange
Black
Green
Yellow
Black
Yellow
Brown
(4) Prong Molex Plugs
Call/Send Harness
Lift Harness
Blue
Blue
Yellow
White
Red
Red
(3) Prong Molex Plugs
TOP LANDING GATE