1
Fig. 10b
7
Fig. 12
2
CLOCKWISE
CLOSES
CONTROL STOP
IMPORTANT:
To avoid overflowing, the SUPPLY STOP (3)
must never be opened to the point where the flow from
the valve exceeds the flow capacity of the fixture. The
fixture must be able to handle a continuous flow in case
of a flush valve failure.
1.
After installation is complete, peel off the PROTECTIVE
FILM
(1)
from the sensor. Standing to one side, block the
sensor with your hand for 10 seconds.
Remove your hand and listen for audible “click” from
within the valve.
2.
Remove COVER
(2)
from SUPPLY STOP
(3)
.Turn on
water supply 1/4 turn to 1/2 turn(CCW) and test for leaks.
Note:
Unit may flush for approximately 5 to 10 sec. when
water is first turned on. If flow persists, turn water off and
repeat step #1 above.
3.
Actuate the FLUSH VALVE:
A) Cover sensor with hand for 10 seconds.
NOTE: Stand outside of sensor detection aera.
B) Remove hand from in front of the sensor; unit will
flush in approximately 3 seconds.
4.
Adjust SUPPLY STOP
(3)
after each flush until the stated
flush volume is achieved, no splashing occurs and the
fixture is properly cleansed.
5.
When adjustment is complete, replace COVER
(2)
and tighten to ensure vandal-resistance.
ADJUST SUPPLY STOP; Fig. 12
Fig. 11
Fig. 11a
Fig. 11b
INSTALL CONDUIT, ESCUTCHEON
AND SENSOR CABLE; Fig. 11
1.
Remove COVER ASSEMBLY
(1)
.
See step seven to
remove the COVER ASSEMBLY
(1)
.
Fig. 9a.
2.
Thread CONDUIT
(2)
into COVER ASSEMBLY
(1)
and
secure by tightening LOCK NUT
(3)
.
Fig. 11a.
3.
Slide ESCUTCHEON
(4)
onto CONDUIT
(2). Fig. 11b.
4.
Feed the 27" CABLE EXTENSION
(5)
thru CONDUIT
(2)
and
connect the CABLE END
(5a)
to the SENSOR
CABLE
(7)
in the COVER ASSEMBLY
(1)
.
Fig. 11b.
Tuck SENSOR CABLE
(5)
into
COVER ASSEMBLY
(1).
5.
Insert CONDUIT
(2)
into hole in wall while replacing
COVER ASSEMBLY
(1).
Rotate until key engages then
tighten SET SCREW
(1)
.
Fig. 9c, 9d.
Note:
If space between wall and valve are too tight, the
CONDUIT (2) will have to be removed and replaced
after the COVER ASSEMBLY (1) is installed.
6.
Slide ESCUTCHEON
(4)
tight against finished wall and
secure by tightening SET SCREW
(7). Fig. 11b.
3
1.
Pull the DOWN TUBE
(7)
up to meet the threaded
FLUSH VALVE CONNECTION
(8)
and hand tighten
the VACUUM BREAKER COUPLING NUT
(6)
. Align
all components of the flush valve assembly.
Fig. 10b.
2.
Lightly tighten the COUPLING NUT
(5)
connection first,
then the VACUUM BREAKER COUPLING NUT
(6)
and
finally the SPUD COUPLING NUT
(9)
. Once alligned
correctly, use a wrench to tighten couplings to make
water tight connections.
Fig. 10b.
INSTALL FLUSH VALVE; Fig. 10b
3
2
1
1
4
5
5a
6
7
2
COUNTER-CLOCKWISE
OPENS CONTROL STOP
12
REMOVE COVER
M965218 REV 1.8
7
9
6
2
5
8
121mm,+13mm, -6mm
(4-3/4)(+1/2, -1/4)
10
11