background image

1

Fig. 10b

7

Fig. 12

2

CLOCKWISE

 CLOSES

CONTROL STOP

IMPORTANT:

 

To avoid overflowing, the SUPPLY STOP (3) 

must never be opened to the point where the flow from 

the valve exceeds the flow capacity of the fixture. The 

fixture must be able to handle a continuous flow in case 

of a flush valve failure.

1.

 After installation is complete, peel off the PROTECTIVE 

    FILM 

(1)

 from the sensor. Standing to one side, block the 

    sensor with your hand for 10 seconds. 

Remove your hand and listen for audible “click” from 

within the valve. 

2.

 Remove COVER 

(2)

 from SUPPLY STOP 

(3)

.Turn on 

    water supply 1/4 turn to 1/2 turn(CCW) and test for leaks. 

Note:

 

Unit may flush for approximately 5 to 10 sec. when 

water is first turned on. If flow persists, turn water off and 

repeat step #1 above. 

3.

 Actuate the FLUSH VALVE:

     A) Cover sensor with hand for 10 seconds. 

             NOTE: Stand outside of sensor detection aera.

     B) Remove hand from in front of the sensor; unit will

          flush in approximately 3 seconds.

4.

 Adjust SUPPLY STOP 

(3)

 after each flush until the stated 

    flush volume is achieved, no splashing occurs and the 

    fixture is properly cleansed. 

5.

 When adjustment is complete, replace COVER 

(2)

    and tighten to ensure vandal-resistance.

ADJUST SUPPLY STOP; Fig. 12

Fig. 11

Fig. 11a

Fig. 11b

     INSTALL CONDUIT, ESCUTCHEON

AND SENSOR CABLE; Fig. 11

1. 

Remove COVER ASSEMBLY 

(1)

.  

See step seven  to 

   remove the COVER ASSEMBLY

 

(1)

Fig. 9a.

2. 

Thread CONDUIT 

(2)

 into COVER ASSEMBLY 

(1)

 and 

    secure by tightening LOCK NUT 

(3)

Fig. 11a.

3.

 Slide ESCUTCHEON 

(4)

 onto CONDUIT 

(2). Fig. 11b.

 

4.

 Feed the 27" CABLE EXTENSION  

(5)

 thru CONDUIT 

(2)

    

and

 

connect the CABLE END 

(5a)

 to the SENSOR 

    CABLE 

(7)

 in the COVER ASSEMBLY 

(1)

Fig. 11b.

    

Tuck SENSOR CABLE 

(5) 

into 

 

COVER ASSEMBLY 

(1).

5. 

Insert CONDUIT 

(2) 

into hole in wall while replacing 

    COVER ASSEMBLY 

(1).

 Rotate until key engages then

     tighten SET SCREW 

(1)

Fig. 9c, 9d. 

Note: 

If space between wall and valve are too tight, the 

CONDUIT (2) will have to be removed and replaced 

after the COVER ASSEMBLY (1) is installed.

6. 

Slide ESCUTCHEON 

(4) 

tight against finished wall and 

    secure by tightening SET SCREW 

(7). Fig. 11b.

 

3

1. 

 Pull the DOWN TUBE 

(7)

 up to meet the threaded 

    FLUSH VALVE CONNECTION 

(8)

 and hand tighten 

    the VACUUM BREAKER COUPLING NUT 

(6)

. Align 

    all components of the flush valve assembly. 

Fig. 10b.

2.

 Lightly tighten the COUPLING NUT 

(5)

 connection first,

    then the VACUUM BREAKER COUPLING NUT 

(6)

 and 

    finally the SPUD COUPLING NUT 

(9)

. Once alligned 

    correctly, use a wrench to tighten couplings to make 

    water tight connections. 

Fig. 10b.

 INSTALL FLUSH VALVE; Fig. 10b

3

2

1

1

4

5

5a

6

7

2

COUNTER-CLOCKWISE

OPENS CONTROL STOP

12

REMOVE COVER

M965218 REV 1.8 

7

9

6

2

5

8

121mm,+13mm, -6mm

(4-3/4)(+1/2, -1/4)

10

11

Содержание Selectronic 6061.013

Страница 1: ...1 sensor for entire Selectronic line of faucets urinals and flush valves Range can be adjusted manually or with optional remote control M965218 REV 1 8 6062 013 6062 025 6062 051 6062 101 6061 013 60...

Страница 2: ...t a l l a t i o n I n s t ru c t i o n s I n s t a l l a t i o n I n s t ru c t i o n s In Toronto Area only 1 905 3061093 Certified to comply with ASME A112 19 2M 2011 AS America Inc NOTE TO INSTALLE...

Страница 3: ...2mm 2 7 8 DETECTION ZONE 400mm 800mm 15 3 4 TO 31 1 2 SUPPLY DN 20mm 3 4 I P S 15 FINISHED WALL FINISHED TILE WALL NOTE INSTALL PLASTER RING SO THAT SCREW HOLES ARE ON THE LEFT AND RIGHT SIDE OF BOX F...

Страница 4: ...Connect White and Black power connections to POWER SUPPLY 1 2 Una la 27 EXTENSI N DE CABLE 3 AL CABLE DE SUMINISTRO DE ENERG A 1a Fig 4a 3 After POWER SUPPLY 1 is installed and wire connections are c...

Страница 5: ...UPPLY 2 into ELECTRICAL BOX 1 Connect White and Black power connections to POWER SUPPLY 2 Connect the POWER CABLE 3 from the power supply to the SPLITTER 4 3 Connect the 27 CABLE EXTENSION 5 to the SP...

Страница 6: ...pply line Fig 5 1 Measure the distance A from the finished wall to the center of the inlet spud on the fixture 2 Cut the supply pipe 1 1 4 A B C shorter then the measurement taken in Step 1 File any r...

Страница 7: ...he right and pull off Fig 9b 3 Rotate bottom half of FLUSH VALVE 3 180 Fig 9b 4 Replace COVER 2 and rotate until key engages than tighten SET SCREW 1 Fig 9c 9d 8 LEFT OR RIGHT HAND INSTALLATION Fig 9...

Страница 8: ...g 11 Fig 11a Fig 11b INSTALL CONDUIT ESCUTCHEON AND SENSOR CABLE Fig 11 1 Remove COVER ASSEMBLY 1 See step seven to remove the COVER ASSEMBLY 1 Fig 9a 2 Thread CONDUIT 2 into COVER ASSEMBLY 1 and secu...

Страница 9: ...in 30 50mm in front of the sensor Fig 14a 4 When the LED 6 stops blinking and stays ON move your hand to the desired position from sensor detection zone 1 1 2 to 31 38 to 787mm and hold in place until...

Страница 10: ...UTOMATIC FLUSH WAS IT SUCCESSFUL 1 COVER SENSOR FOR 10 SECONDS 2 UNCOVER SENSOR FOR 10 SECONDS MANUAL VALVE OBSTRUCTED CLOSE STOP VALVE AND SERVICE RETRY AUTO FLUSH UNIT IS CONTINUOUSLY FLUSHING PUSH...

Отзывы: