3
INSTALL ELECTRICAL BOX
ASSEMBLY; Fig. 3
1.
Drill a 2" diameter hole in the finished wall for the
conduit tube from the flush valve at the dimension
shown.
Fig.3.
2.
Cut a 127x127mm (5"x 5") opening in finished wall for
2-GANG ELECTRICAL BOX
(1)
(not supplied) at the
dimensions shown.
3.
Feed SENSOR CABLE
(2)
through wall opening and
out 2" diameter hole.
Important:
Make sure the smaller end of the SENSOR
CABLE (2) goes through the 2" diameter hole.
4.
Install 2-GANG ELECTRICAL BOX
(1).
Note:
The 2-GANG ELECTRICAL BOX (1) can be
installed in any location along the 180˚ arc.
1
INSTALL POWER SUPPLY AND
MAKE ELECTRICAL CONNECTIONS;
Fig. 4
CAUTION
Turn power supply OFF before
making connections
1.
Mount POWER SUPPLY
(1)
into 2-GANG ELECTRICAL
BOX
(2).
Connect White and Black power connections to
POWER SUPPLY
(1)
.
2.
Una la 27" EXTENSIÓN DE CABLE
(3)
AL CABLE DE
SUMINISTRO DE ENERGÍA
(1a)
.
Fig. 4a.
3.
After POWER SUPPLY
(1)
is installed and wire
connections are completed install the FRONT PANEL
FRAME
(4)
to the 2-GANG ELECTRICAL BOX
(2). Fig. 4b.
4
. Install the two Tabs on the back side of the FRONT
PANEL
(5)
into the two Slots located on the top edge of
the FRONT PANEL FRAME
(4).
Push on bottom until it
snaps into place.
Fig. 4b.
2
SUPPLY
DN 20mm
(3/4" I.P.S.)
SUPPLY
DN 20mm
(3/4" I.P.S.)
M965218 REV 1.8
Fig.3 (TOP SPUD FIXTURE ILLUSTRATED)
1
127mm
(5")
80mm
(3-3/8")
(51mm) 2" DIA.
HOLE FOR
CONDUIT
127mm
(5")
305mm
(12" MAX.)
180˚
45˚
C/L OF
FIXTURE
SMALL END
2
2
Detail A.
3/4" TOP SPUD
BLACK & WHITE
POWER
CONNECTIONS
3
1a
Fig.4
Fig.4a
Fig.4b
1
TABS
SLOT
SLOT
CONNECTOR NOT USED
IN THIS INSTALLATION
C/L OF
FIXTURE
2
C/L OF
FIXTURE
4
5
2
Hubbel-RACO 8231 4"
ELECTRICAL BOX
OR EQUIVALENT BY
CONTRACTOR
Hubbel-RACO 779