3

    INSTALL ELECTRICAL BOX

ASSEMBLY; Fig. 3

1.

 Drill a 2" diameter hole in the finished wall for the 

   conduit tube from the flush valve at the dimension 

   shown. 

Fig.3.

2.

 Cut a 127x127mm (5"x 5") opening in finished wall for 

    2-GANG ELECTRICAL BOX 

(1) 

(not supplied) at the 

    dimensions shown.

3.

 Feed SENSOR CABLE 

(2)

 through wall opening and 

    out 2" diameter hole. 

Important:

 

Make sure the smaller end of the SENSOR 

CABLE (2) goes through the 2" diameter hole.   

4.

 Install 2-GANG ELECTRICAL BOX 

(1). 

Note:

 

The 2-GANG ELECTRICAL BOX (1) can be 

installed in any location along the 180˚ arc.

 

1

    INSTALL POWER SUPPLY AND

MAKE ELECTRICAL CONNECTIONS;

Fig. 4

CAUTION

Turn power supply OFF before

making connections

1.

 Mount POWER SUPPLY 

(1)

 into 2-GANG   ELECTRICAL

   BOX 

(2). 

Connect White and Black power connections to 

   POWER SUPPLY 

(1)

.

2. 

Una la 27" EXTENSIÓN DE CABLE 

(3)

 AL CABLE DE

   SUMINISTRO DE ENERGÍA 

(1a)

.

 Fig. 4a.

3.

 After POWER SUPPLY 

(1)

 is installed and wire 

    connections are completed install the FRONT PANEL 

    FRAME 

(4)

 to the 2-GANG ELECTRICAL BOX 

(2). Fig. 4b.

4

. Install the two Tabs on the back side of the FRONT 

    PANEL 

(5)

 into the two Slots located on the top edge of 

    the FRONT PANEL FRAME 

(4).

 Push on bottom until it 

    snaps into place. 

Fig. 4b.

    

2

SUPPLY

DN 20mm

(3/4" I.P.S.)

SUPPLY

DN 20mm

(3/4" I.P.S.)

M965218 REV 1.8 

Fig.3 (TOP SPUD FIXTURE ILLUSTRATED) 

1

127mm

(5")

80mm

(3-3/8")

(51mm) 2" DIA.

HOLE FOR

CONDUIT

127mm

(5")

305mm

(12" MAX.)    

180˚

45˚

C/L OF

FIXTURE

SMALL END

2

2

Detail A.

3/4" TOP SPUD

BLACK & WHITE

POWER

CONNECTIONS

3

1a

Fig.4 

Fig.4a 

Fig.4b 

1

TABS

SLOT

SLOT

CONNECTOR NOT USED

IN THIS INSTALLATION

C/L OF

FIXTURE

2

C/L OF

FIXTURE

4

5

2

Hubbel-RACO 8231 4"

ELECTRICAL BOX

OR EQUIVALENT BY

CONTRACTOR

Hubbel-RACO 779

Содержание Selectronic 6061.013

Страница 1: ...1 sensor for entire Selectronic line of faucets urinals and flush valves Range can be adjusted manually or with optional remote control M965218 REV 1 8 6062 013 6062 025 6062 051 6062 101 6061 013 60...

Страница 2: ...t a l l a t i o n I n s t ru c t i o n s I n s t a l l a t i o n I n s t ru c t i o n s In Toronto Area only 1 905 3061093 Certified to comply with ASME A112 19 2M 2011 AS America Inc NOTE TO INSTALLE...

Страница 3: ...2mm 2 7 8 DETECTION ZONE 400mm 800mm 15 3 4 TO 31 1 2 SUPPLY DN 20mm 3 4 I P S 15 FINISHED WALL FINISHED TILE WALL NOTE INSTALL PLASTER RING SO THAT SCREW HOLES ARE ON THE LEFT AND RIGHT SIDE OF BOX F...

Страница 4: ...Connect White and Black power connections to POWER SUPPLY 1 2 Una la 27 EXTENSI N DE CABLE 3 AL CABLE DE SUMINISTRO DE ENERG A 1a Fig 4a 3 After POWER SUPPLY 1 is installed and wire connections are c...

Страница 5: ...UPPLY 2 into ELECTRICAL BOX 1 Connect White and Black power connections to POWER SUPPLY 2 Connect the POWER CABLE 3 from the power supply to the SPLITTER 4 3 Connect the 27 CABLE EXTENSION 5 to the SP...

Страница 6: ...pply line Fig 5 1 Measure the distance A from the finished wall to the center of the inlet spud on the fixture 2 Cut the supply pipe 1 1 4 A B C shorter then the measurement taken in Step 1 File any r...

Страница 7: ...he right and pull off Fig 9b 3 Rotate bottom half of FLUSH VALVE 3 180 Fig 9b 4 Replace COVER 2 and rotate until key engages than tighten SET SCREW 1 Fig 9c 9d 8 LEFT OR RIGHT HAND INSTALLATION Fig 9...

Страница 8: ...g 11 Fig 11a Fig 11b INSTALL CONDUIT ESCUTCHEON AND SENSOR CABLE Fig 11 1 Remove COVER ASSEMBLY 1 See step seven to remove the COVER ASSEMBLY 1 Fig 9a 2 Thread CONDUIT 2 into COVER ASSEMBLY 1 and secu...

Страница 9: ...in 30 50mm in front of the sensor Fig 14a 4 When the LED 6 stops blinking and stays ON move your hand to the desired position from sensor detection zone 1 1 2 to 31 38 to 787mm and hold in place until...

Страница 10: ...UTOMATIC FLUSH WAS IT SUCCESSFUL 1 COVER SENSOR FOR 10 SECONDS 2 UNCOVER SENSOR FOR 10 SECONDS MANUAL VALVE OBSTRUCTED CLOSE STOP VALVE AND SERVICE RETRY AUTO FLUSH UNIT IS CONTINUOUSLY FLUSHING PUSH...