background image

1

1

4

2

3

Fig. 6

1.

 Measure from finished wall to first thread of Adapter 

    or threaded supply pipe (dimension “X”). Cut 

    COVER TUBE 

(1)

 to length (X). Apply Teflon Tape to 

    the threaded end of the Adapter or supply pipe. 

Fig. 6a.

 

2.

 Push the COVER TUBE 

(1)

 into the WALL ESCUTCHEON 

    

(2)

. Slide both onto the SUPPLY PIPE 

(3)

Fig. 6b.

3.

 Push the COVER TUBE 

(1)

 in to expose the threads of 

    the supply pipe. Fig. 4c. With a wrench thread the 

    SUPPLY STOP 

(4)

 onto the SUPPLY PIPE 

(3)

. Align and 

    tighten. 

Fig. 6c.

4. 

Pull COVER TUBE 

(1)

 against SUPPLY STOP 

(4) 

and 

    push WALL ESCUTCHEON 

(2)

 against finished wall. 

 

  

5

    INSTALL COVER TUBE, WALL
ESCUTCHEON and SUPPLY STOP;
Fig. 6

5

TEFLON TAPE

FINISHED WALL

    INSTALL THE SWEAT SOLDER

ADAPTER; Fig. 5

CAUTION

Turn  water supplies off

before beginning

Note: 

 

Install Optional Sweat Solder Adapter 

(Supplied) for copper pipe supply line.

 

Fig. 5.

1.

 Measure the distance (A) from the finished wall to the 

    center of the inlet spud on the fixture.

2.

 Cut the supply pipe 1-1/4" (A-B=C) shorter then the 

    measurement taken in Step 1. File any rough edges off 

    the end of the supply pipe.

3.

 Clean the end of the supply pipe. Push the threaded 

    Adapter on until it is seated against the internal stop. 

    Sweat the Adapter to the pipe.

4

CENTER LINE OF

FIXTURE SPUD

FINISHED WALL

FILE EDGES

SOLDER

ADAPTER

Fig.5 

ADAPTER

32mm

(1-1/4")

A

(A-B)=

B

C

X

X

CLEAN

1. 

Place the SPUD FLANGE 

(1)

 over the spud on 

    the Fixture.

2.

 Thread SPUD COUPLING NUT 

(2)

 onto Spud. 

    Make sure SEAL WASHER 

(3)

 and FRICTION 

    WASHER 

(4)

 are installed. Do not tighten fully.

3.

 Insert the DOWN TUBE 

(5)

 into the SPUD 

    COUPLING NUT 

(2)

 and push it down.

Note:

 

If cutting Down Tube (5) to size, note that 

Critical Line (C/L) on Vacuum Breaker must 

typically be 6

"

 (152mm) above fixture. Consult Code 

for details.

 

    INSTALL DOWN TUBE AND
VACUUM BREAKER; Fig. 7

6

Fig. 6a

Fig. 6b

Fig. 6c

2

M965218 REV 1.8 

1

2

3

4

5

Fig. 7

3/4" TOP SPUD

Содержание Selectronic 6061.013

Страница 1: ...1 sensor for entire Selectronic line of faucets urinals and flush valves Range can be adjusted manually or with optional remote control M965218 REV 1 8 6062 013 6062 025 6062 051 6062 101 6061 013 60...

Страница 2: ...t a l l a t i o n I n s t ru c t i o n s I n s t a l l a t i o n I n s t ru c t i o n s In Toronto Area only 1 905 3061093 Certified to comply with ASME A112 19 2M 2011 AS America Inc NOTE TO INSTALLE...

Страница 3: ...2mm 2 7 8 DETECTION ZONE 400mm 800mm 15 3 4 TO 31 1 2 SUPPLY DN 20mm 3 4 I P S 15 FINISHED WALL FINISHED TILE WALL NOTE INSTALL PLASTER RING SO THAT SCREW HOLES ARE ON THE LEFT AND RIGHT SIDE OF BOX F...

Страница 4: ...Connect White and Black power connections to POWER SUPPLY 1 2 Una la 27 EXTENSI N DE CABLE 3 AL CABLE DE SUMINISTRO DE ENERG A 1a Fig 4a 3 After POWER SUPPLY 1 is installed and wire connections are c...

Страница 5: ...UPPLY 2 into ELECTRICAL BOX 1 Connect White and Black power connections to POWER SUPPLY 2 Connect the POWER CABLE 3 from the power supply to the SPLITTER 4 3 Connect the 27 CABLE EXTENSION 5 to the SP...

Страница 6: ...pply line Fig 5 1 Measure the distance A from the finished wall to the center of the inlet spud on the fixture 2 Cut the supply pipe 1 1 4 A B C shorter then the measurement taken in Step 1 File any r...

Страница 7: ...he right and pull off Fig 9b 3 Rotate bottom half of FLUSH VALVE 3 180 Fig 9b 4 Replace COVER 2 and rotate until key engages than tighten SET SCREW 1 Fig 9c 9d 8 LEFT OR RIGHT HAND INSTALLATION Fig 9...

Страница 8: ...g 11 Fig 11a Fig 11b INSTALL CONDUIT ESCUTCHEON AND SENSOR CABLE Fig 11 1 Remove COVER ASSEMBLY 1 See step seven to remove the COVER ASSEMBLY 1 Fig 9a 2 Thread CONDUIT 2 into COVER ASSEMBLY 1 and secu...

Страница 9: ...in 30 50mm in front of the sensor Fig 14a 4 When the LED 6 stops blinking and stays ON move your hand to the desired position from sensor detection zone 1 1 2 to 31 38 to 787mm and hold in place until...

Страница 10: ...UTOMATIC FLUSH WAS IT SUCCESSFUL 1 COVER SENSOR FOR 10 SECONDS 2 UNCOVER SENSOR FOR 10 SECONDS MANUAL VALVE OBSTRUCTED CLOSE STOP VALVE AND SERVICE RETRY AUTO FLUSH UNIT IS CONTINUOUSLY FLUSHING PUSH...