6
1
CLOCKWISE
CLOSES
CONTROL STOP
COUNTER-CLOCKWISE
OPENS CONTROL STOP
REMOVE COVER
Fig. 8
1.
Remove COVER
(1)
from SUPPLY STOP
(2)
.
2.
With a flat blade screwdriver open SUPPLY STOP
(2)
.
3.
Turn on water supply to flush line of any debris or
sediment.
4.
Close SUPPLY STOP
(2)
and replace COVER
(1)
.
FLUSH OUT SUPPLY LINES; Fig. 8
7
4
Fig. 9a
Fig. 9c
Fig. 9d
Fig. 9
3
The UNIT is shipped with the inlet flange on the right
side. If needed, the orientation can be reversed by
following the steps below.
1.
Loosen SET SCREW
(1)
with 2.5mm Hex Wrench
(4)
in back of top half of FLUSH VALVE
(2)
.
Fig. 9a.
2.
Rotate COVER
(2)
to the right and pull off.
Fig. 9b.
3.
Rotate bottom half of FLUSH VALVE
(3)
180˚.
Fig. 9b.
4.
Replace COVER
(2)
and rotate until key engages than
tighten SET SCREW
(1)
.
Fig. 9c, 9d.
8 LEFT OR RIGHT HAND
INSTALLATION; Fig. 9
8
4
2
2
KEY
2
2
1
3
Fig. 9b
180˚
Fig. 10a
3
2
5
1
1.
Insert the side INLET FLANGE
(1)
on the FLUSH
VALVE
(2)
into the SUPPLY STOP
(3)
. Lubricate the
INLET FLANGE O-RING
(4)
with water if necessary.
Lightly tighten COUPLING NUT
(5)
.
Fig. 10a.
Important:
Do not use lubricants (other than water)
or any type of thread sealing paste or tape.
2.
Align the FLUSH VALVE
(2) (Fig. 10b)
directly above
the DOWN TUBE
(7)
and VACUUM BREAKER
COUPLING NUT
(6)
. Make sure that GASKET
(10)
is installed.
Note:
There is a +13mm, -6mm (+1/2, -1/4) tolerance
for the 121mm (4-3/4) dimension.
Fig. 10b.
INSTALL FLUSH VALVE; Fig. 10a
9
4
2
1
M965218 REV 1.8