OPERATING
30
recipes into the controller’s memory.
To skip these steps press enter for each probe color.
To set the recipe for each probe use
and
buttons to scroll thru the preset recipe names and numbers. Press
when done to move to the next probe. After the recipes have been set for all four probes the controller will alternately
display
the
food temperature screen
and the
air temperature screen
Note:
For an explanation of the displayed parameters see Fig.8, page 28
.
To start the cycle press
.
The controller will alternately display the food temperature screen and air temperature screen. During the cycle,
the time left to run is shown in the lower right corner of the display. The refrigeration system (fans, compressor, and
evaporator) will start to operate. The fans will operate continuously; the compressor will cycle as required to maintain the
programmed temperature range.
The timer will count down from H 2:00 Min (the programmed cycle time). When it reaches H 00:00 Min, the air
temperature will rise to the programmed hold temperature range and the unit will go into the “HOLDING MODE”. It will
remain there until the cycle is stopped by pressing
.
F.2.3. Defrost Cycle
Make sure the unit is on and the display shows:
The controller asks the operator to choose an operating cycle. Choose between
automatic, manual, defrost, UV, and print cycle. To start the defrost cycle press
.
Note:
There are two types of defrost available: air flow type and electric heat type defrost. If your unit is equipped with air
flow type defrost, open the door to continue. For electric heat type defrost the door has to be closed. Depending on which
type defrost your unit is equipped with, the controller will display one of the following messages:
Press
to start the cycle.
If air flow is the default defrost type selected for your unit (see chapter D.5.3.), the controller will display:
The controller will display the remaining time of the air flow type defrost cycle. The
total time of the cycle depends on the preset cycle time (see chapter D.5.3).
If the default defrost type for your unit is electric heat, the controller will display:
The defrost cycle will be on until the defrost temperature reaches the programmed
end defrost temperature.
At the end of the cycle the controller will beep
and display the message:
Содержание Blast Chiller AP40BC250-12
Страница 5: ...CONTROLLER 3...
Страница 12: ...INSTALLATION 10 PHOTO 4 PHOTO 5...
Страница 14: ...INSTALLATION 12 PHOTO 7 Door magnetic switch on the left Magnet on the right PHOTO 8...
Страница 38: ...APPENDIXES 36 Appendix 2 Electrical Schematic 1...
Страница 39: ...APPENDIXES 37 Appendix 3 Electrical Schematic 2...