4.
(For installation on Concrete or Block) Drill three each 5/16” (or 8 mm) holes at the marked
locations. Insert the supplied ¼” (6 mm) Steel expansion bolts into the holes.
5.
(For wall installation) Locate a stud and use supplied mounting screws or hollow Wall
Anchors. To use the hollow wall anchors, drill 5/16” holes at marked locations and insert
the anchors into the hole. A combination of mounting screws and anchors is acceptable.
6.
Remove the cover of water heater from carton.
7.
Position the water heater into place. Fasten to the wall.
ELECTRICAL
Ensure compliance with applicable electrical codes during installation
including the U.S. National Electric Code (NFPA 70) or the Canadian
Electrical Code – Part 1 (CGAS C22.1) depending on location.
1.
Ensure that a properly grounded 120 V/ 60 Hz three prong outlet is available.
DO NOT PLUG IN THE UNIT UNTIL INSTALLATION IS COMPLETE, TESTED, AND READY FOR
INITIAL START UP.
WIRED REMOTE CONTROL
Choose a location for the optional wired controller to be installed per the following specifications
and in compliance with all local code requirements.
1.
The controller should be located out of the reach of small children.
2.
Avoid installing in an area where set point can be adjusted by non-authorized personnel.
3.
Avoid locations where the controller can become wet or be splashed.
4.
The cable for the temperature controller shall be a non-polarized two core cable 24 AWG
minimum gauge. The maximum recommended cable length is 328’ (100 m).
5.
Pull wire from remote location to water heater.
6.
ENSURE POWER TO WATER HEATER IS DISCONNECTED! Remove cover from unit.
7.
Terminate wires at the Remote Control Terminals as shown threading the wire through wire
guides.