Page 10
H2O SAVER TECHNOLOGY™ - Set a Desired Volume
1.
The volume display range is 0-250 gallons when system is set to use English
units or 0-950 liters when in metric mode.
2.
Press the “MODE” key briefly to display the message “F4”, then press the “UP”
( or “DOWN”) key. The mode will switch from temperature display mode to
water quantity display mode.
3.
Displayed volume: Please note that the readout indicates the water quantity divided by ten
(10). Example – if the display shows “10”, this correlates to a volume of 10x10 = 100 gallons
(English unit mode) or 100 liters (metric unit mode).
4.
Adjust the “Volume Set Point” by pressing the “UP” or “DOWN” key briefly. Each press
corresponds to a change of 10 gallons of volume (English unit mode) or a change of 50 liter
(metric mode).
Example 1: English unit mode: The digit 7 is currently being displayed. This indicates a set
point of 70 gallons. Pressing the “UP” key once changes the set point to “8” indicating a
water quantity of 8×10 = 80 gallons as the new set point.
Example 2: Metric unit mode: The digit 25 is displayed. This indicates a set point of 250
liters. Pressing the “UP” key once changes the display to “30” indicating a water quantity of
30x10 = 300 liters as the new set point.
5.
When the water heater is discharging water to the bathtub and the volume set point is
reached, the alarm on the remote controller will sound an alert for about 10 seconds.
Note: The output of hot water will not stop automatically.
IMPORTANT! The volume measurement only keeps track of the water
volume that passes through the water heater. For example, if hot water
going to a tub is combined with cold water, the volume computed would not be representative of
the total amount that may have filled the tub. This could lead to an overflow or damage!
Monitoring the Volume Delivered
Press the “MODE” key. The message “F3” will be displayed. Press the “UP” (or DOWN) key
briefly. The mode will switch from temperature display mode to water quantity display mode.
The water volume already delivered is displayed. Example: “5” = 5×10 (50L or 50G).
Power Outage
In the event of a power outage or if the unit is unplugged, settings are restored to their factory
default values.