background image

 

SPEEDDOME ULTRA VII CAMERA DOME CONFIGURATION UTILITY 

8200-0184-09, REV. A 

OPERATOR’S MANUAL SUPPLEMENT 

1 of 13

 

SpeedDome

®

 Ultra VII 

Camera Dome 
Configuration Utility 

Operator’s Manual Supplement 

 

 

RAS915/RAS916/RAS917 Series 

Contents 

About this Supplement .......................................... 1

 

New SpeedDome Ultra VII Features..................... 1

 

Quick Set Menu..................................................... 2

 

Auto Iris/Auto Focus Resume Setting ................... 3

 

Scan Limits ............................................................ 4

 

AD Up-the-Coax Protocol...................................... 5

 

SensorNet and RS-422 Matrix Switchers and 

Controllers ........................................................ 6

 

Panasonic UTC Protocol Preset Programming..... 9

 

Specifications-SDU VII ........................................ 10

 

Specifications-22X Camera................................. 11

 

Specifications-23X Day/Night Camera................ 12

 

Declarations ........................................................ 13

 

 

 

© 2004 Sensormatic 

About this Supplement 

This supplement provides detailed information 
about SpeedDome Ultra VII camera dome features 
that are not currently covered in your operator’s 
manual. This supplements information found in the 
following manuals: 

• 

22x Camera Dome Configuration Utility 
Operator’s Manual, 8200-0184-02 

• 

Day/Night Camera Dome Configuration Utility 
Operator’s Manual, 8200-0184-04 

NOTE:

 Keep this supplement with your operator’s 

manual for reference purposes. 

If you need assistance... 

Contact your Sales Representative. 

New SpeedDome Ultra VII 

Features 

SpeedDome Ultra VII provides the following 
features with firmware version 0710-0147-0106 
and newer.  

• 

Quick Set Menu for accessing commonly used 
dome settings 

• 

Auto Iris/Auto Focus resume settings  

• 

Scan Limits for establishing start and stop points 
for monitoring a specific area 

• 

AD Up-the-Coax protocol for compatible 
American Dynamics controllers 

In addition, updated information is provided for the 
following: 

• 

SensorNet and RS-422 matrix switchers and 
controllers 

• 

Preset programming instructions for the 
Panasonic WJ-SX550 multiplexer and 
WV-CU550A controller 

Содержание RAS915

Страница 1: ...d in your operator s manual This supplements information found in the following manuals 22x Camera Dome Configuration Utility Operator s Manual 8200 0184 02 Day Night Camera Dome Configuration Utility...

Страница 2: ...button varies by controller Table 1 provides a description of the available options Table 1 Quick Set Menu Options Command Description 0 Quick Set Toggle Quick Set Menu Toggles between displaying and...

Страница 3: ...is supported For more information about these settings see your SpeedDome Ultra VII Configuration Utility Operator s Manual See also Topic Page Auto Iris Auto Focus Resume Setting 3 Scan Limits 4 AD...

Страница 4: ...e solid line curve represents the scan area By setting the left and right scan limits where the building s wall becomes visible you ensure that only useful video of the parking lot is being observed w...

Страница 5: ...nds provided in this document assume that one of these keyboards is being used Contact your Sales Representative for current information AD UTC Command Summary Table 3 lists the commands to operate th...

Страница 6: ...Resume Auto Focus mode F Function Iris Open Or F Function Iris Close Resume Auto Iris mode Flip Rotate dome 180 from current position flip Performance Notes Keep the following considerations in mind...

Страница 7: ...me for each pattern cannot exceed 6 minutes 50 seconds Total dome commands used in all patterns cannot exceed 99 3 Requires firmware version 0701 2833 0103 EEPROM 0701 2834 0201 Flash PROM or newer VM...

Страница 8: ...roadcast address AD168 Supported Protocol SensorNet 1 RS 422 1 or 2 Maximum Presets 16 1 2 64 1 3 or 60 4 Maximum Patterns 5 3 Quick Set Menu Not supported Address Range SensorNet 1 180 RS 422 1 99 1...

Страница 9: ...e converter 2 Preset information is stored at the converter not the dome 3 Requires AD2083 02 with firmware version 0701 11YB 156A or newer Preset information is stored in the dome not the converter 4...

Страница 10: ...n 9 To program more Presets repeat steps 5 through 8 To exit the Dome Configuration Menu and save changes press F4 Exit To verify the Preset programming enter a Preset number 1 64 and press Preset Spe...

Страница 11: ...d at 9 8V 1A 20V 25A 500W 8 20 s impulse Alarm Input TVS rated at 9 8V 1A 20V 25A 500W 8 20 s impulse Alarms Inputs Control Outputs When no I O board is used Inputs 1 dry contact 3 5mA sink Outputs 1...

Страница 12: ...ing System 2 1 interlace Video Out 1 0 Vp p 75 ohms composite Signal to Noise 50 dB typical Horizontal Resolution 470 lines at center Minimum Illumination 0 5 lux AGC On 20 IRE 0 03 lux with s open sh...

Страница 13: ...empowered to provide the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIME...

Отзывы: