background image

 

SPEEDDOME ULTRA VII CAMERA DOME CONFIGURATION UTILITY 

8200-0184-09, REV. A 

OPERATOR’S MANUAL SUPPLEMENT 

10 of 13

 

5.  Use the joystick to move the highlight to 

Presets

. Press 

Set

 to select. The 

Select 

Preset to Program

 screen displays. 

SELECT PRESET TO PROGRAM

PRESET

NUMBER

PRESET NAME

1-96

PRESET 1-96

FOCUS FAR to program preset

EXIT

 

6.  Use the joystick to select the Preset you want 

to program. If the Preset has been 
programmed the dome automatically moves to 
that position. 

 

Move the joystick right to increase the 
preset number. 

 

Move the joystick left to decrease the 
preset number. 

When the correct Preset number appears, 
press 

Set

 to begin programming. 

7. The 

Presets

 screen displays. Use the joystick 

to adjust the dome to the correct pan/tilt 
position. 

PRESETS

PRESET X

Position camera with PAN

TILT, ZOOM and IRIS

FOCUS FAR to save and exit

EXIT

 

IMPORTANT!

 If using the WV-CU550A 

Controller with the WJ-SX550 Multiplexer, you 
must press 

F3

 (A. Res) to adjust the zoom, 

focus, or iris settings. This places the controller 
in normal navigating mode. Make the 
necessary adjustments. When finished, press 

F1

 (On) to resume menu mode. 

8. Press 

Set

 to save the Preset information. 

9.  To program more Presets, repeat steps 5 

through 8. To exit the 

Dome Configuration 

Menu

 and save changes, press 

F4

 (Exit). 

To verify the Preset programming, enter a Preset 
number (1-64) and press Preset. 

Specifications-Indoor Dome 

Operational 

Pan/Tilt: 

Manual Pan Speed......................... 0.2°-100° per second 
 

(scaled to zoom position) 

Manual Tilt Speed ........................ 0.25°-100° per second 
 

(scaled to zoom position) 

Preset Pan/Tilt Speed ............220° per second maximum 

Pan Travel..................................360° continuous rotation 

Tilt Travel ..................................................................>90° 

Pan/Tilt Accuracy .....................................................±0.5° 

22X Camera Zoom Functions: 

Optical Zoom..............................................................22X 

Digital Zoom ...............................................................11X 

Zoom Pause......................................... 22X selectable or  
 33X 

default 

Total Zoom ...............................................................242X 

Maximum Zoom Stop .......44X, 66X, 88X (default), 110X,  
 

132X, 154X, 176X, 198X, 220X, 242X 

Zoom/Focus Accuracy ........................................... ±0.5% 

23x Day/Night

 Camera Zoom Functions: 

Optical Zoom..............................................................23X 

Digital Zoom ...............................................................10X 

Zoom Pause......................................... 23X selectable or  
 35X 

default 

Total Zoom ...............................................................230X 

Maximum Zoom Stop .......46X, 69X, 92X (default), 115X,  
 

138X, 161X, 184X, 207X, 230X 

Zoom/Focus Accuracy ........................................... ±0.5% 

Auto Synchronization: 

Line Locked.........................Remote V-phase adjustment 

Internal ..........................................Built-in sync generator 

Address Range ....................................................... 1-255 

Number of Presets: 

VM16 / ADTT16 ........................... 96 with SensorNet 485 

VM32 / AD32................................ 96 with SensorNet 485 

AD2150 ............................................. 64 with Manchester 
 

16 with RS422 (using AD2083-02A) 

VM96......................Virtual with RS422 or SensorNet 485 

VM168 / AD168................................ 64 with Manchester,  
 

RS-422 or SensorNet 

 

16 with RS422 (using AD2083-02A) 

AD2050 ............................................. 64 with Manchester 
 

16 with RS422 (using AD2083-02A) 

Содержание RAS915

Страница 1: ...d in your operator s manual This supplements information found in the following manuals 22x Camera Dome Configuration Utility Operator s Manual 8200 0184 02 Day Night Camera Dome Configuration Utility...

Страница 2: ...button varies by controller Table 1 provides a description of the available options Table 1 Quick Set Menu Options Command Description 0 Quick Set Toggle Quick Set Menu Toggles between displaying and...

Страница 3: ...is supported For more information about these settings see your SpeedDome Ultra VII Configuration Utility Operator s Manual See also Topic Page Auto Iris Auto Focus Resume Setting 3 Scan Limits 4 AD...

Страница 4: ...e solid line curve represents the scan area By setting the left and right scan limits where the building s wall becomes visible you ensure that only useful video of the parking lot is being observed w...

Страница 5: ...nds provided in this document assume that one of these keyboards is being used Contact your Sales Representative for current information AD UTC Command Summary Table 3 lists the commands to operate th...

Страница 6: ...Resume Auto Focus mode F Function Iris Open Or F Function Iris Close Resume Auto Iris mode Flip Rotate dome 180 from current position flip Performance Notes Keep the following considerations in mind...

Страница 7: ...me for each pattern cannot exceed 6 minutes 50 seconds Total dome commands used in all patterns cannot exceed 99 3 Requires firmware version 0701 2833 0103 EEPROM 0701 2834 0201 Flash PROM or newer VM...

Страница 8: ...roadcast address AD168 Supported Protocol SensorNet 1 RS 422 1 or 2 Maximum Presets 16 1 2 64 1 3 or 60 4 Maximum Patterns 5 3 Quick Set Menu Not supported Address Range SensorNet 1 180 RS 422 1 99 1...

Страница 9: ...e converter 2 Preset information is stored at the converter not the dome 3 Requires AD2083 02 with firmware version 0701 11YB 156A or newer Preset information is stored in the dome not the converter 4...

Страница 10: ...n 9 To program more Presets repeat steps 5 through 8 To exit the Dome Configuration Menu and save changes press F4 Exit To verify the Preset programming enter a Preset number 1 64 and press Preset Spe...

Страница 11: ...d at 9 8V 1A 20V 25A 500W 8 20 s impulse Alarm Input TVS rated at 9 8V 1A 20V 25A 500W 8 20 s impulse Alarms Inputs Control Outputs When no I O board is used Inputs 1 dry contact 3 5mA sink Outputs 1...

Страница 12: ...ing System 2 1 interlace Video Out 1 0 Vp p 75 ohms composite Signal to Noise 50 dB typical Horizontal Resolution 470 lines at center Minimum Illumination 0 5 lux AGC On 20 IRE 0 03 lux with s open sh...

Страница 13: ...empowered to provide the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIME...

Отзывы: