Command Description 

14+Quick Set*   WDR Off: Disables Wide 

Dynamic Range (WDR). Use this 
setting when the light level is 
constant or changes in lighting 
conditions are gradual. 

15+Quick Set  

Smooth Scan: Initiates a smooth 
scan between the left and right 
scan limits, starting at the left 
scan limit. If no scan limits have 
been set, initiates a smooth 360° 
clockwise rotation around the 
dome axis using the current tilt, 
zoom and focus settings.  

16+Quick Set  

Stepped Scan: Initiates a scan 
between the left and right scan 
limits pausing briefly every 10° (at 
1x zoom), starting at the left scan 
limit. When the right scan limit is 
reached, the scan is reversed. If 
no scan limits have been set, 
initiates a clockwise rotation 
around the dome axis pausing 
briefly every 10° (at 1x zoom) for 
3 seconds using the current tilt, 
zoom and focus settings.  

17+Quick Set  

Random Scan: Initiates a scan 
between the left and right scan 
limits pausing randomly between 
the limits. If no scan limits have 
been set, initiates a clockwise or 
counter-clockwise rotation around 
the dome axis using the current 
tilt, zoom and focus settings. The 
dome pauses randomly as it 
rotates around the axis. 

20+Quick Set  

Dome Information: Displays the 
Dome Information screen 
available through the dome 
configuration menu. 

Refer to your controller manual to determine if the 
Quick Set Menu feature is supported. For more 
information about these settings, see your 
SpeedDome Ultra VII Configuration Utility 
Operator’s Manual. See also: 

Topic Page 

Auto Iris/Auto Focus Resume Setting 

Scan Limits 

AD Up-the-Coax Protocol 

SensorNet and RS-422 Matrix 
Switchers and Controllers 

Auto Iris/Auto Focus 
Resume Setting 

Normally, the camera’s iris and focus settings 
return to automatic mode when the dome moves a 
minimum of one frame from its current pointing 
position. In some situations, you may want to 
maintain specific iris and/or focus adjustments 
based upon your surveillance needs. 

Use the 

I/F Return to Auto

 setting on the 

Pan/Tilt/Zoom/Sync Opts

 menu to configure the 

auto iris and auto focus resume settings. 

Figure 3: Pan/Tilt/Zoom/Sync Options menu 

PROPORTIONAL FLIP

OFF/ON

1ST ZOOM STOP X

33/22 

MAX TOTAL ZOOM X

44...242 

LINE LOCK

ON/OFF

FREEZE FRAME

OFF/ON

I/F RETURN TO AUTO

OFF/ON/
IRIS/FOCUS

 

 

Four settings are available: On, Off, Iris and Focus. 

Setting Description 

On  

Both return to auto iris and return to 
auto focus settings are 

enabled

Moving the dome resumes auto mode 
for both iris and focus changes. 

Off 

Both return to auto iris and return to 
auto focus settings are 

disabled

Moving the dome does not resume 
auto mode for iris and focus changes. 

Iris 

Only return to auto iris is enabled.

 

Return to auto focus is disabled. 
Moving the dome resumes auto iris 
mode without changing focus settings. 

Focus  

Only return to auto focus is 
enabled. 

Return to auto iris is 

disabled. Moving the dome resumes 
auto focus mode without changing iris 
settings. 

Continue with Changing the Auto Iris/Auto Focus 
Resume Setting on page 4 to configure the setting. 

Содержание RAS915

Страница 1: ...d in your operator s manual This supplements information found in the following manuals 22x Camera Dome Configuration Utility Operator s Manual 8200 0184 02 Day Night Camera Dome Configuration Utility...

Страница 2: ...button varies by controller Table 1 provides a description of the available options Table 1 Quick Set Menu Options Command Description 0 Quick Set Toggle Quick Set Menu Toggles between displaying and...

Страница 3: ...is supported For more information about these settings see your SpeedDome Ultra VII Configuration Utility Operator s Manual See also Topic Page Auto Iris Auto Focus Resume Setting 3 Scan Limits 4 AD...

Страница 4: ...e solid line curve represents the scan area By setting the left and right scan limits where the building s wall becomes visible you ensure that only useful video of the parking lot is being observed w...

Страница 5: ...nds provided in this document assume that one of these keyboards is being used Contact your Sales Representative for current information AD UTC Command Summary Table 3 lists the commands to operate th...

Страница 6: ...Resume Auto Focus mode F Function Iris Open Or F Function Iris Close Resume Auto Iris mode Flip Rotate dome 180 from current position flip Performance Notes Keep the following considerations in mind...

Страница 7: ...me for each pattern cannot exceed 6 minutes 50 seconds Total dome commands used in all patterns cannot exceed 99 3 Requires firmware version 0701 2833 0103 EEPROM 0701 2834 0201 Flash PROM or newer VM...

Страница 8: ...roadcast address AD168 Supported Protocol SensorNet 1 RS 422 1 or 2 Maximum Presets 16 1 2 64 1 3 or 60 4 Maximum Patterns 5 3 Quick Set Menu Not supported Address Range SensorNet 1 180 RS 422 1 99 1...

Страница 9: ...e converter 2 Preset information is stored at the converter not the dome 3 Requires AD2083 02 with firmware version 0701 11YB 156A or newer Preset information is stored in the dome not the converter 4...

Страница 10: ...n 9 To program more Presets repeat steps 5 through 8 To exit the Dome Configuration Menu and save changes press F4 Exit To verify the Preset programming enter a Preset number 1 64 and press Preset Spe...

Страница 11: ...d at 9 8V 1A 20V 25A 500W 8 20 s impulse Alarm Input TVS rated at 9 8V 1A 20V 25A 500W 8 20 s impulse Alarms Inputs Control Outputs When no I O board is used Inputs 1 dry contact 3 5mA sink Outputs 1...

Страница 12: ...ing System 2 1 interlace Video Out 1 0 Vp p 75 ohms composite Signal to Noise 50 dB typical Horizontal Resolution 470 lines at center Minimum Illumination 0 5 lux AGC On 20 IRE 0 03 lux with s open sh...

Страница 13: ...empowered to provide the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIME...

Отзывы: