background image

 

SPEEDDOME ULTRA VII CAMERA DOME CONFIGURATION UTILITY 

8200-0184-09, REV. A 

OPERATOR’S MANUAL SUPPLEMENT 

6 of 13

 

Command Function 

 (Zoom In) or 

Twist joystick 
clockwise 

Move the cursor to the right of 
the current character in the 
name or password. 

 (Zoom Out) 

or Twist joystick 
counterclockwise 

Move the cursor to the left of 
the current character in the 
name. 

Additional Dome Commands 

Table 5 provides the special commands available 
when using the dome in an AD-UTC network. 
These commands are available when you enter the 
keyboard combination provided. 

Table 5: Additional Dome Commands 

Command Function 

F

 (Function), 

Preset # (1-96), and 

then 

(Preset) 

Program selected Preset 

Preset # (1-96), and 

then 

(Preset) 

Recall selected Preset 

F

(Function), 

pattern # (1-3), and 

then 

 

 

(Shift+Preset) 

Start selected Pattern 
programming 

Pattern # (1-3), and 

then 

F

(Function) 

Save Pattern programming 

Pattern # (1-3), and 

then 

 

 

(Shift and Preset) 

Run selected Pattern 
continuously 

F

 

 

(FFocus Far)  

Or 

F

 

  

(FFocus 
Near) 

Resume Auto Focus mode 

F

 

 

(FIris Open) 

Or 

F

 

  

(FIris Close) 

Resume Auto Iris mode 

 (Flip) 

Rotate dome 180° from current 
position (“flip”) 

Performance Notes 

Keep the following considerations in mind when 
using the SpeedDome Ultra VII camera dome in 
the AD-UTC environment. 

Address Setting 

The SpeedDome Ultra VII camera dome must be 
set to address 891 to operate in the AD-UTC 
environment. When the dome initializes or resets, 
the address and protocol information (UTC_T) 
appear on-screen. 

Accessing the Quick Set Menu 

The Quick Set Menu provides easy access to 
specific SpeedDome Ultra VII functions from the 
keyboard. To access the Quick Set menu, select 

the dome, and press 

 (Quick Set button). 

See Quick Set Menu on page 2 for information 
about the Quick Set functions. 

SensorNet and RS-422 
Matrix Switchers and 
Controllers 

The following provides information about 
SensorNet and RS-422 controllers compatible with 
SpeedDome Ultra VII. Specific operating 
considerations are also included. 

VM8  

Supported Protocol 

SensorNet 

Maximum Presets 

Maximum Patterns (1) 

Quick Set Menu 

Not supported 

Address Range 

1-8 

Notes: 

(1)  Apple Peel only. Programmable patterns are 

not available. 

Содержание RAS915

Страница 1: ...d in your operator s manual This supplements information found in the following manuals 22x Camera Dome Configuration Utility Operator s Manual 8200 0184 02 Day Night Camera Dome Configuration Utility...

Страница 2: ...button varies by controller Table 1 provides a description of the available options Table 1 Quick Set Menu Options Command Description 0 Quick Set Toggle Quick Set Menu Toggles between displaying and...

Страница 3: ...is supported For more information about these settings see your SpeedDome Ultra VII Configuration Utility Operator s Manual See also Topic Page Auto Iris Auto Focus Resume Setting 3 Scan Limits 4 AD...

Страница 4: ...e solid line curve represents the scan area By setting the left and right scan limits where the building s wall becomes visible you ensure that only useful video of the parking lot is being observed w...

Страница 5: ...nds provided in this document assume that one of these keyboards is being used Contact your Sales Representative for current information AD UTC Command Summary Table 3 lists the commands to operate th...

Страница 6: ...Resume Auto Focus mode F Function Iris Open Or F Function Iris Close Resume Auto Iris mode Flip Rotate dome 180 from current position flip Performance Notes Keep the following considerations in mind...

Страница 7: ...me for each pattern cannot exceed 6 minutes 50 seconds Total dome commands used in all patterns cannot exceed 99 3 Requires firmware version 0701 2833 0103 EEPROM 0701 2834 0201 Flash PROM or newer VM...

Страница 8: ...roadcast address AD168 Supported Protocol SensorNet 1 RS 422 1 or 2 Maximum Presets 16 1 2 64 1 3 or 60 4 Maximum Patterns 5 3 Quick Set Menu Not supported Address Range SensorNet 1 180 RS 422 1 99 1...

Страница 9: ...e converter 2 Preset information is stored at the converter not the dome 3 Requires AD2083 02 with firmware version 0701 11YB 156A or newer Preset information is stored in the dome not the converter 4...

Страница 10: ...n 9 To program more Presets repeat steps 5 through 8 To exit the Dome Configuration Menu and save changes press F4 Exit To verify the Preset programming enter a Preset number 1 64 and press Preset Spe...

Страница 11: ...d at 9 8V 1A 20V 25A 500W 8 20 s impulse Alarm Input TVS rated at 9 8V 1A 20V 25A 500W 8 20 s impulse Alarms Inputs Control Outputs When no I O board is used Inputs 1 dry contact 3 5mA sink Outputs 1...

Страница 12: ...ing System 2 1 interlace Video Out 1 0 Vp p 75 ohms composite Signal to Noise 50 dB typical Horizontal Resolution 470 lines at center Minimum Illumination 0 5 lux AGC On 20 IRE 0 03 lux with s open sh...

Страница 13: ...empowered to provide the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIME...