26
American Dryer Corp.
113068 - 10
G. STEAM INFORMATION
It is your responsibility to have
ALL
plumbing connections made by a qualified professional to assure that the
steam plumbing installation is adequate and conforms with local and state regulations or codes.
IMPORTANT:
Failure to comply with the requirements stipulated in this manual can result in
component failure, which will VOID THE WARRANTY.
NOTE:
The dryer is manufactured with a pneumatic (piston) damper system, which requires an
external supply of clean, dry, and regulated air (80 psi +/- 10 psi [5.51 bar +/- 0.68 bar]).
1. Steam Coil pH Level
The normal for copper type steam coils
must be
maintained between a value of 8.5 to 9.5. For steel type
steam coils the pH level
must be
maintained between a value of 9.5 to 10.5. These limits are set to limit
the acid attack of the steam coils.
IMPORTANT:
Coil failure due to improper pH level will VOID THE WARRANTY.
2. Steam Requirements – High Pressure
Inlet---------2” supply line connection
Return------1-1/4” return line connection
e
r
u
s
s
e
r
P
m
a
e
t
S
g
n
i
t
a
r
e
p
O
m
u
m
i
x
a
M
g
i
s
p
0
5
1
*
a
P
k
2
6
8
)
d
a
o
L
l
a
m
r
o
N
(
t
u
p
n
I
t
a
e
H
p
h
B
0
6
)
e
t
a
m
i
x
o
r
p
p
A
(
n
o
it
p
m
u
s
n
o
C
r
h
/
b
l
1
7
0
,
2
r
h
/
g
k
9
3
.
9
3
9
Shaded areas are stated in metric equivalents
* The minimum operating pressure for optimum results is 100 psig (689.47 kPa).
3. Installation Instructions
To ensure that adequate supply of steam is provided, be sure that the steam supply lines and steam return
lines are sized and laid out as stipulated in this manual. Inadequate steam supply lines and steam return
lines or improper steam plumbing will result in poor performance and can cause component failure. Clean,
dry, and regulated steam
must be
provided to the dryer.
IMPORTANT:
Steam coil failure due to water hammer by wet steam will VOID THE WARRANTY.
a. The presence of the condensate in the steam supply will cause water hammer and subsequent heat
exchanger (steam coil) failure. The steam supply connection into the main supply line
must be
made
with a minimum 10-inch (25.4 cm) riser. This will prevent any condensate from draining towards the
dryer.