113068 - 10
www.amdry.com
15
c. Annunciator, Optional Pendant, Over-Burner, and Resistance Temperature Detector (RTD) Cable
Remove the four (4) bolts that hold on the character panel. Open the door to the main electrical
enclosure, the female end of the RTD cable will be found there. Loosen the 1-inch lock nut and remove
the modified hole seal. Put the female end of the RTD cable through the hole in the top of the electrical
enclosure. Connect the male end and the female end of the RTD cable together, pull the cable up until
the threads of the reducing bushing can be seen through the hole into where the character panel was.
Next, get the 1-inch lock nut on by a few threads, slip the modified hole seal under the lock nut holding
the 45° cord grip connector, then tighten the 1-inch lock nut. Replace the character panel and tighten
the four (4) bolts.