B. LOCATION REQUIREMENTS
Before installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of such
codes or ordinances the location
must conform
with the National Fuel Gas Code ANSI.Z223.1 LATEST
EDITION, or in Canada, the installation
must conform
to applicable Canadian Standards: CAN/CGA-B149.1-
M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General
Installation and Gas Plumbing).
The dryer requires 36-inches (91.44 cm) of space on each side of the dryer and 36-inches (91.44 cm) of space
behind the unit for ease of maintenance and tilting. The dryer
must be
leveled for proper operation. If shimming
is required, put 9-1/2” x 9-1/2” (24.13 cm x 24.13 cm) metal shims under the base feet. The dryer
must be
lagged to the floor.
IMPORTANT:
Dryer
should be
located where a minimum amount of exhaust duct
will be
necessary.
1. The dryer
must be
installed with a proper exhaust duct connection to the outside.
2. The dryer
must be
installed with provisions for adequate combustion and make-up air supply.
CAUTION:
This dryer produces combustible lint and
must be
exhausted to the outdoors. Every 6
months, inspect the exhaust ducting and remove any lint build up.
IMPORTANT: Dryer
must be
installed in a location/environment, which the ambient
temperature remains between 40° F (4.44° C) and 130° F (54.44° C).