E. FRESH AIR SUPPLY REQUIREMENTS
When the dryer is operating, it draws in room air, heats this air through the basket (tumbler), and exhausts it out
of the building. Therefore, the room air
must be
continually replenished from the outdoors. If make-up air is
inadequate, drying time and efficiency will be adversely affected, and safety will be compromised. Premature
component failure may result.
Air supply (make-up air)
must be
given careful consideration to assure proper performance of each dryer. An
unrestricted source of air is necessary for each dryer. An airflow of 13,000 cfm (368 cmm)
must be
supplied to
each dryer. As a general rule, an unrestricted air entrance from the outdoors (atmosphere) of a minimum 20
square feet (6.096 square meters) is required for each dryer.
To compensate for the use of registers or louvers used over the openings, the make-up air area
must be
increased by approximately thirty-three percent (33%). Make-up air openings
should not be
located in an area
directly near where exhaust vents exit the building.
Allowances
must be
made for remote or constricting passageways or where dryers are located at excessive
altitude or predominantly low pressure areas. The dryer
must be
installed with provisions for adequate combustion
and make-up air supply.
IMPORTANT:
Make-up air
must be
provided from a source free of dry cleaning solvent fumes.
Make-up air that is contaminated by dry cleaning solvent fumes will result in
irreparable damage to the motors and other dryer components.
NOTE:
Component failure due to dry cleaning solvent fumes will VOID THE WARRANTY.
F. EXHAUST REQUIREMENTS
1. General Exhaust Ductwork Information
Exhaust ductwork
should be
designed and installed by a qualified professional. Improperly sized ductwork
will create excessive back pressure, which results in slow drying, increased use of energy, overheating of
the dryer, and shutdown of the burner by the airflow (sail) switches, burner hi-limits, or basket (tumbler)
hi-limit thermostats. The dryer
must be
installed with a proper exhaust duct connection to the outside.
CAUTION:
This dryer produces combustible lint and
must be
exhausted to the outdoors.
CAUTION: IMPROPERLY SIZED OR INSTALLED EXHAUST DUCTWORK CAN
CREATE A
POTENTIAL FIRE HAZARD.
NOTE:
THE DRYER
MUST BE
INDEPENDENTLY EXHAUSTED.
COMMON
DUCTWORK
IS
NOT
ACCEPTABLE
.
The exhaust ductwork
should be
laid out in such a way that the ductwork travels as directly as possible to
the outdoors with as few turns as possible. Single or independent dryer venting is recommended.
Содержание Phase 7 Gas/Steam AD-464
Страница 11: ...113068 10 www amdry com 7 B DIMENSIONS GAS AND STEAM ...
Страница 27: ...113068 10 www amdry com 23 ...
Страница 28: ...24 American Dryer Corp 113068 10 ...
Страница 62: ...ADC Part No 113068 10 05 22 12 ...