113354 - 20
www.adclaundry.com
47
B. ADJUSTMENTS
7 DAYS AFTER INSTALLATION AND EVERY 6 MONTHS THEREAFTER
Inspect bolts, nuts, screws, setscrews, grounding connections, and nonpermanent gas connections (i.e., unions,
shutoff valves, and orifices). Fan (impellor) V-belts, along with the motor and drive belts
should be
examined
and replaced if necessary. Tighten loose V-belts when necessary. Complete operational check of controls and
valves. Complete operational check of
ALL
safety devices (i.e., door switches, lint drawer switch, sail switch,
burner, and hi-limit thermostats).
Squirrel cage type fan (impellor) on the blower motor
must be
inspected and cleaned every 6 months.
C. LUBRICATION
The fan shaft bearing, and
ALL
the tumbler drive shaft and idler shaft bearings
must be
lubricated every 3
months. Use a #2 Alvania grease or its equivalent. Lubrication is necessary or premature bearing failure will be
the result.
The motor bearings are permanently lubricated and
DO NOT
require to be serviced.