113354 - 20
www.adclaundry.com
23
F. ELECTRICAL INFORMATION
1. Electrical Requirements
It is your responsibility to have
ALL
electrical connections made by a properly licensed and competent
electrician to ensure that the electrical installation is adequate and conforms to local and state regulations or
codes. In the absence of such codes,
ALL
electrical connections, materials, and workmanship
must
conform
to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST
EDITION or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
IMPORTANT:
Failure to comply with these codes or ordinances, and/or the requirements stipulated
in this manual can result in personal injury or component failure.
NOTE:
Component failure due to improper installation will VOID THE WARRANTY.
Each dryer
should be
connected to an independently protected branch circuit. The dryer
must be
connected
with copper wire only.
DO NOT use
aluminum
wire;
it
could
create
a
fire
hazard
. The copper
conductor wire/cable
must be
of proper ampacity and insulation in accordance with electric codes for
making
ALL
service connections.
NOTE:
The use of aluminum wire will VOID THE WARRANTY.
NOTE:
Wiring diagrams are affixed to the inside at the top front control door and the rear upper back
guard/panel or the left side panel area behind the control door.
Outside Ductwork Protection
To protect the outside end of the horizontal ductwork from the weather, a 90° elbow bent downward
should be
installed where the exhaust exits the building. If the exhaust ductwork travels vertically up
through the roof, it
should be
protected from the weather by using a 180° turn to point the opening
downward. In either case, allow at least twice the diameter of the duct between the duct opening and the
nearest obstruction.
IMPORTANT:
DO NOT
use screens, louvers, or caps on the outside opening of the exhaust
ductwork.
Содержание ML-190
Страница 34: ...30 American Dryer Corp 113354 20 ...
Страница 62: ...ADC Part No 113354 20 10 23 14 ...