Actual electrical wire connections are made to the L1 and L2 terminals of the motor contactor located
in the rear service box mentioned above. The ground connection is also made to the copper lug also
provided in this box.
If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord/
pigtail (wire size
must conform
to rating of dryer), or the dryer can be hard wired directly to the
service breaker panel. In both cases, a strain relief
must be
installed where the wiring enters the
dryer.
2) 3-Phase (3ø) Wiring Connections/Hookup (for Non-Reversing Models Only)
The electrical connections on
ALL
3-phase
(3ø)
gas and steam dryers are made into the rear service
box located at the upper left area of the dryer. Electrical connections for electrically heated dryers
are made in the electric oven area located at the upper rear area of the dryer.
NOTE
:
A CIRCUIT SERVING EACH DRYER
MUST BE
PROVIDED.
If local codes permit, power to a gas or steam dryer can be made by the use of a flexible U.L. listed
power cord/pigtail (wire size
must conform
to rating of dryer), or the dryer can be hard wired
directly to the service breaker panel. In
ALL
cases, a strain relief
must be
installed where the wiring
enters the dryer.