F. ELECTRICAL INFORMATION
1. Electrical Requirements
It is your responsibility to have
ALL
electrical connections made by a properly licensed and competent
electrician to assure that the electrical installation is adequate and conforms with local and state regulations
or codes. In the absence of such codes,
ALL
electrical connections, material, and workmanship
must
conform
to the applicable requirements of the National Electrical Code ANSI/NFPA NO.70-LATEST
EDITION.
IMPORTANT
: Failure to comply with these codes or ordinances, and/or the requirements
stipulated in this manual can result in personal injury or component failure.
NOTE
: Component failure due to improper installation will VOID THE WARRANTY.
Each dryer
should be
connected to an independently protected branch circuit. The dryer
must be
connected
with copper wire only.
DO NOT
use aluminum wire which could cause a fire hazard. The copper conductor
wire/cable
must be
of proper ampicity and insulation in accordance with electric codes for making
ALL
service connections.
NOTE
: The use of aluminum wire will VOID THE WARRANTY.
IMPORTANT
: A separate circuit servicing each dryer
must be
provided.