C. DRYER ENCLOSURE REQUIREMENTS
Bulkheads and partitions
should be
made of noncombustible materials and
must be
located a minimum of
12-inches (18-inches or more is recommended for ease of installation, maintenance , and service) above the
dryer outer top, except along the front of the dryer which may be partially closed in if desired. The clearance
between the bulkhead header and the dryer
must be
a minimum of four (4) inches and
must not
extend more
than four (4) inches to the rear of the front. The bulkhead facing
must not
be closed in all the way to the top of
the dryer. A one (1) inch clearance is required.
NOTE
: Allowances
must be
made for opening the control door.
Dryers may be positioned side wall to side wall. However, a 1/16" minimum allowance
must be
made for
opening and closing of the control door and the lint door. It is suggested that the dryer be positioned about two
(2) feet away from the nearest obstruction for ease of installation, maintenance, and service (to be measured
from the back guard.) (Refer to the
illustration above
for details.)
NOTE
: Air considerations are important for proper and efficient operation.
IMPORTANT
: Even though a minimum of only 12-inches is required, 18-inches or more is
suggested. The additional clearance is advantageous for ease of installation and
service.
IMPORTANT
: When fire sprinkler systems are located above the dryers, a minimum of
18-inches above the dryer console (module) is required. Dryers may be
positioned side wall to side wall however, a 1/16-inch minimum allowance is
required between dryers (or wall) for ease of installation and maintenance.
Allowances
must be
made for the opening and closings of the control door and
the lint door.