46
6. Lint drawer/screen are not being cleaned on a regular basis or often enough.
7. Extractors (washers) are not performing properly.
8. Sail switch is fluttering...restriction in exhaust ductwork (for GAS MODELS ONLY).
9. Failed microprocessor controller (computer)...temperature calibration is inaccurate.
10. Failed microprocessor temperature sensor calibration is inaccurate.
11. Failed burner hi-limit (for GAS MODELS ONLY).
12. Failed lint chamber hi-heat protector thermostat.
13. Steam damper system is not functioning properly (for STEAM MODELS ONLY)...
a. Steam damper sticking closed.
b. Leak in the pneumatic system.
c. Flow control incorrectly set.
S.
Condensation on main door glass...
1. Too long, undersized, or improperly installed ductwork.
2. Customer furnished back draft damper in ductwork is sticking in partially closed position.
T.
Dryer is making scraping noise at basket (tumbler) area...
1. Check for object caught in basket (tumbler)/wrapper area.
2. Basket (tumbler) is out of proper alignment...
a. Check both the vertical alignment and the lateral alignment.
b. Check gap between the front panel and the basket (tumbler), setscrews may have come loose and the
basket (tumbler) walked forward or back.
3. Loose basket (tumbler) tie rod.
4. Failed basket (tumbler) support.
U.
Excessive noise and/or vibration...
1. Dryer is not leveled properly.
2. Impellor (fan/blower) is out of balance.
a. Excessive lint build up on impellor (fan/blower).
Содержание AD-81 II