42
2. Failed arc suppressor (A.S.) board.
3. Failed microprocessor controller (computer).
D. Drive motor operates okay for a few minutes, and then stops and will not restart...
1. Motor is overheating and tripping out on internal overload protector...
a. Motor air vents clogged with lint.
b. Low voltage to the motor.
c. Failed motor.
d. Basket (tumbler) is binding...check for an obstruction.
e. Failed idler bearings or basket (tumbler) bearings.
E.
Blower motor is not operating (does not start)...
1. Failed blower motor contactor (relay).
2. Failed arc suppressor (A.S.) board.
3. Failed motor.
4. Failed microprocessor controller (computer).
F.
Blower motor operates okay for a few minutes, and then stops and will not restart...
1. Motor is overheating and tripping out on internal overload protector...
a. Motor air vent is clogged with lint.
b. Low voltage to the motor.
c. Failed motor.
d. Failed (out of balance) impellor (fan/blower).
G.
Both drive motor and blower motor are not operating (does not start)...microprocessor controller
(computer) motor indicator dots are on...
1. Failed arc suppressor (A.S.) board.
2. Failed microprocessor controller (computer).
H. Both drive motor and blower motor run a few minutes and stop...microprocessor controller
(computer) light emitting diode (L.E.D.) display continues to read time or percent of extraction
and ALL indicator dots are off...