SECTION X
BURNER AND BASKET (TUMBLER)/LINT CHAMBER
MANUAL RESET HI-LIMIT INSTRUCTIONS
I M P O R T A N T
MANUAL RESET HI-LIMIT INSTRUCTIONS
FOR DUAL TIMER OR PHASE 5 WITHOUT HEAT FAULT
This dryer was manufactured with a burner manual reset hi-limit thermostat. If the burner manual reset
hi-limit thermostat is open prior to the start of the drying cycle, or during the cycle, the dryer will not recognize
the open state of the burner hi-limit thermostat and will start or continue through the drying cycle with no heat.
M anual reset hi-limit thermostat
must be
reset manually.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper burner oven
operation.
The location of the manual reset hi-limit switch is on the right side of the burner box.
IMPORTANT
This dryer is equipped with a burner
hi-limit and tumbler/lint chamber hi-limit
thermostat which must be reset manually.