6
SECTION II
SPECIFICATIONS/COMPONENT IDENTIFICATION
A. SPECIFICATIONS
*
Refer to
Electrical Service Specifications
chart on
page 21
.
IMPORTANT:
Steam dryers
must be
provided with a clean, dry, and regulated 80 PSI +/- 10 PSI
(5.51 bars +/- 0.68 bars) air supply. Air volume requirement is 0.75 cfh (cubic feet
per hour) - 0.02 cmh (cubic meters per hour).
NOTE: ADC
reserves the right to make changes in specifications at any time without notice or
obligation.
BASKET (TUMBLER) DIAMETER
37”
94 cm
BASKET (TUMBLER) DEPTH
36”
91.5 cm
BASKET (TUMBLER) MOTOR
1/2 HP
0.373 kw
BLOWER MOTOR
3 HP
2.238 kw
DOOR OPENING (DIAMETER)
21-1/2”
54.61 cm
BASKET (TUMBLER) VOLUME
22.4 cu. ft.
0.634 cu. m.
DRYERS PER 20'/40' CONTAINER
10/20
DRYERS PER 48'/53' TRUCK
24/26
VOLTAGE AVAILABLE*
208-460v 3ø 50/60 Hz
APPROX. WEIGHT (UNCRATED)
756 lbs
342.9 kg
APPROX. WEIGHT (CRATED)
806 lbs
365.6 kg
HEAT INPUT
270,000 btu/hr
68,040 kcal/hr
AIRFLOW
1,700 cfm
48.14 cmm
INLET PIPE SIZE
1” F.P.T.
VOLTAGE AVAILABLE*
208-460v 3ø 50/60 Hz
APPROX. WEIGHT (UNCRATED)
789 lbs
357.9 kg
APPROX. WEIGHT (CRATED)
839 lbs
380.6 kg
AIRFLOW
1,700 cfm
48.14 cmm
AIR VOLUME
0.75 cfh
0.02 cmh
AIR CONNECTION
1/8” F.P.T.
STEAM CONSUMPTION
BOILER HP
NORMAL LOAD
375 lbs/hr
170.5 kg/hr
11
OPERATING STEAM PRESSURE
STEAM SUPPLY
STEAM RETURN
125 PSI max
8.6
bars
1” N.P.T.
1” N.P.T.
Shaded areas are stated in metric equivalents
Gas
Steam
Содержание AD-81 II
Страница 23: ...19 ...
Страница 59: ...ADC 113311 1 02 06 01 35 2 09 19 01 25 ...