American Dryer Corp.

113576 - 1

Non-Coin Programming ___________________

Phase 7.2 Non-Coin Diagnostic Codes

MAIN DOOR OPENED – A main door or door circuit is open.

EXHAUST HIGH TEMP FAULT – Tumbler is above 180° F
(82.2° C).

LINT ACCESS OPEN – Lint drawer or lint door circuit is open.

EXHAUST HIGH LIMIT FAULT – Temp. disk under tumbler is
open.

SAIL SWITCH CLOSED FAULT – Sail switch is closed –
should be open at the start of a cycle.

SAIL SWITCH OPEN FAULT – Sail switch remained open after
the cycle started.  Should have closed.

BURNER HIGH LIMIT FAULT – Burner temp. disk has opened.

BURNER IGNITION CONTROL – No signal to gas valve from
(DSI) module during trial for ignition time.  DSI module is bad.

IGNITION FAULT – Gas valve did not remain open after trial
for ignition.  Indicates that no flame was detected.

FLAME FAULT – Flame was detected during trial for ignition
but failed later.

ROTATION FAULT – Indicates the tumbler is not rotating.

OPEN EXHAUST TEMPERATURE PROBE – Indicates the
exhaust temperature probe is open or shorted.

OPEN FIRE SUPPRESSION SYSTEM (F.S.S.) PROBE FAULT
– Indicates the temperature probe for the F.S.S. is open or
shorted.

LOW VOLTAGE FAULT – Volt dropped below the operating
value.

EE PROM FAULT ### – Error in memory location.  Fault
correction:

Enter the program mode by pressing the UP and STOP keys.

Press “4” and ENTER keys in password “FAA” Press UP
ARROW.

Press enter to confirm reset of EE PROM.

Inputs (Red L.E.D.s)

All indications are with L.E.D. lit

ESTOP – Indicates E-STOP has been pressed.

GAS_V – Indicates the gas valve is open (ON).

BRHL – Indicates the burner high limit disk is closed.

SAIL – Indicates the sail switch is closed.

EXHL – Indicates the exhaust high limit disk is closed
(temperature below 190° F [87.8° C]).

MAIN – Indicates the status of main door is closed.

LINT – Indicates the lint drawer is closed.

FUSE – Indicates the status of the control voltage after
POWER ON button has been pressed.

Outputs (Green L.E.D.s)

All indications are with L.E.D. lit

AUX – This is for a spare output to be programmed.

STEAM – Indicates the status of the steam injection output.

_HEAT – Indicates the status of the heat output.

AIR – Indicates the status of the air jet output.

REV – Indicates the status of the tumbler reverse direction
output.

If the request to tumble the drum in the reverse direction is
made, then the L.E.D. is ON.

FWD – This L.E.D. will indicate the status of the tumbler
forward direction output.

FAN – This L.E.D. will indicate the status of the fan output.

Содержание AD-35i

Страница 1: ...76 1 American Dryer Corporation 88 Currant Road Fall River MA 02720 4781 USA Telephone 1 508 678 9000 Fax 1 508 678 9447 e mail techsupport amdry com www adclaundry com To avoid errors and damage to the dryer please read these instructions carefully before attempting to install or operate ...

Страница 2: ...erosene oil paint or wax Items that have been spotted or soaked with vegetable or cooking oil constitute a fire hazard and should not be dried Do not dry mop heads Contaminations from wax or flammable solvents are a fire hazard Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this appliance Aqualified technician must be called if any high limit thermostat trips ...

Страница 3: ...113576 1 www adclaundry com 3 This Page Is Intentionally Left Blank ...

Страница 4: ... 22 9 24 9 Heat Rate Gas kW 20 5 36 6 39 6 Heat Rate Steam Normal Load Bhp 2 7 3 6 Steam Consumption kg hr 47 6 63 5 Electric Oven Size kW 6 7 13 5 18 5 20 4 22 0 18 5 20 4 22 0 Airborne Sound Level dB A 63 64 64 Tumbler Drive Motor kW 0 75 0 75 0 75 Blower Fan Motor kW 0 37 0 56 0 56 Net Weight Approximate kg 250 300 318 Shipping Weight Approximate kg 265 330 327 Cabinet Width A cm 81 0 87 6 99 1...

Страница 5: ...113576 1 www adclaundry com 5 ...

Страница 6: ... 50i 91 cm AD 80i 102 cm G 2 5 cm To allow control door to open H 2 5 cm I 1 5 mm J 1 5 mm Fresh Make Up Air Supply Requirements The dryer draws in air heats it passes it through the tumbler and exhausts it outside Adequate ventilation has to be provided to avoid the back flow of gases into the room from appliances burning fuels including open fires Insufficient fresh air supply could diminish dry...

Страница 7: ...45 in the direction of airflow The main duct diameter should increase before each individual duct is added Multiple Dryer Venting Through End Wall 3x 90 Turns AD 35i AD 50i AD 80i A m 15 80 12 10 B mm 152 203 203 203 Multiple Dryer Venting AD 35i AD 50i AD 80i A mm 152 203 203 B mm 810 876 991 Multiple Dryer Venting Through an End Wall C mm 203 254 254 D mm 254 356 356 E mm 305 406 406 F mm 356 45...

Страница 8: ...d to each dryer Failure to properly earth the dryer will void the warranty An external means of power removal disconnect device must be provided Each dryer should be connected to a properly sized and independently protected branch circuit The electric supply must match exactly what is specified on the dryer s rating plate data badge Electrical Connections The electrical input connections are made ...

Страница 9: ... 21 32 416V 3 13 5 22 32 AD 50i AD 80i Oven kW Amps 220V 1 18 5 89 0 125 230V 1 20 4 93 6 125 240V 1 22 0 96 6 125 220V 3 18 5 53 4 80 230V 3 20 4 56 1 80 240V 3 22 0 57 8 80 380V 3 18 5 34 7 50 400V 3 20 4 36 1 50 416V 3 22 0 37 2 50 NOTES ______________________________________________________ _____________________________________________________________ __________________________________________...

Страница 10: ... top of the dryer for this purpose The length and design of the restraint should be suitable to prevent strain on the gas line if the dryer is moved If the dryer is to be moved then the following steps must be taken Disconnect electrical power to the dryer Close all external gas supply shutoff valves Disconnect the gas supply line Remove the restraint from the dryer CE Approved Gas Types 2nd Famil...

Страница 11: ...Consult factory for elevations over 610m for correct burner injector size s 7 Instructions on how to convert the gas valve is included with the gas valve conversion kit see chart 8 Reverse step 4 to install the gas valve B with manifold D assembly 9 Open shutoff valve in the dryer s gas supply line 10 Test all connections for leaks 11 Connect gas valve wires 12 Continue electric power 13 Provide p...

Страница 12: ...supply connection into the main supply line must be made with a minimum 25 cm riser This will prevent any condensate from draining towards the dryer The steam supply line to the dryer must include a 30 cm riser along with a drip trap and check valve This will prevent any condensate from entering the steam coil Flexible hoses or couplings must be used The dryer vibrates slightly when operating whic...

Страница 13: ... 50i AD 80i 1 Steam Coil 2 Vacuum Breaker 3 Solenoid Valve 4 Flexible Hose or Coupling 5 Riser 6 Strainer 7 Manual Shutoff Valve 8 Drop 9 Dirt Leg 10 Drip Trap 11 Check Valve 12 Inverted Bucket Steam Trap 13 Return Main 14 Supply Main ...

Страница 14: ... with water and mild detergent solution non flammable Alternatively tumble a load of old garments that are wetted with water and mild detergent solution non flammable Preoperational Test A performance check is needed after the dryer is fully installed and before the dryer is ready for use Start the dryer refer to the Operating Instructions below Gas Dryers Check for flame ignition may need more th...

Страница 15: ...s from the factory you can FAX your order to ADC at 1 508 678 9447 or telephone our Parts Department at 1 508 678 9000 Please be prepared to provide the dryer model number serial number description of the part and the part number if known This dryer is equipped with two manually resettable high limit thermostats The burner high limit is located in the top center of the dryer behind the control doo...

Страница 16: ...orted LOW VOLTAGE FAULT Volt dropped below the operating value EE PROM FAULT Error in memory location Fault correction Enter the program mode by pressing the UP and STOP keys Press 4 and ENTER keys in password FAA Press UP ARROW Press enter to confirm reset of EE PROM Inputs Red L E D s All indications are with L E D lit ESTOP Indicates E STOP has been pressed GAS_V Indicates the gas valve is open...

Страница 17: ...g credit coin mode remaining time free mode MED Temps Exhaust left S A F E right Axial middle Axial dryer LO Tumbler RPM S A F E TEST Switch to program mode Press and hold the Pause key until prompted to press MED to open the water L C D Operating Messages When Display Reads Out of Order Pressing LO displays one of the causes listed below MODEL FAULT Wrong model selected at PL01 3rd position SAIL ...

Страница 18: ... shipments will be refused You will be notified if your warranty claim cannot be processed due to insufficient or missing information We must receive this information within 30 days otherwise the claim will be rejected and the part will be discarded For your convenience log the following information Date of Purchase ________________________________ Model Number __________________________________ R...

Отзывы: