Coin Programming ________________________

Enter Programming Mode By Placing

The Programming Switch On The Phase 7 Board Up

While No Cycle Is In Progress.

“Program Mode” Will Then Be Displayed.

Navigating Within The Programming Mode:

“Med” Key To Enter A Program Location.
“Hi-temp” / “Lo-temp” Keys Increase / Decrease
Program Location.
“Pause” Key Rejects Entry And Moves To Next
Program Location.

Changing A Parameter Value:

With Parameter Value Displayed Pressing “Lo Temp”
Or “High Temp” Changes The Parameter Value.
“Med” Key Must Be Pressed To Accept A New Parameter.

Typical Programming Example:

Change a single coin acceptor from factory setting to yield 20
minutes for $.50, $.50 as the minimum amount to start, and no
differential in regard to temperature key selection.

Settings: Time for Amt to Start (PL03, PL04, PL05)  20

Left Coin Denomination (PL06) .............. $ .25
Amount to Start (PL06) ........................... $ .50

Clearing Coin Credit:

NO CYCLE IN PROGRESS AND PROGRAM SWITCH DOWN.

Hold PAUSE while pressing HI 3 times, LO twice, and MED
once.

“Clear Credit?” will appear.  Press any key to complete.

Accessing and Clearing Coin Vault Total

Enter program mode by switching program switch (up) while
no cycle is in progress.

Press HI – “Coin Vault total is $XXX” will appear.

Press HI – “Clear Coin Vault Total?” will appear.

Press MED to clear this amount or PAUSE to leave as is.

Hot Keys:

In the Coin Mode Hot Keys are enabled while in a cycle by
placing the program switch in the program (up) position.

In Free Mode Hot Keys are always enabled.

HI – Remaining credit – coin mode / remaining time – free
mode.

MED – Temps – Exhaust / left, S.A.F.E. / right, Axial / middle
(Axial dryer)

LO – Tumbler RPM

S.A.F.E. TEST: Switch to program mode.  Press and hold the
“Pause” key until prompted to press MED to open the water.

L.C.D. Operating Messages

When Display Reads “Out of Order”

Pressing LO displays one of the causes listed below.

MODEL FAULT – Wrong model selected at PL01/3rd position.

SAIL SWITCH CLOSED – Sail switch closed before starting.

SAIL SWITCH OPEN – Sail switch failed to close after starting.

BURNER HI-LIMIT – Oven thermostat switch has opened.

EXHAUST HI-LIMIT – Tumbler thermostat switch has opened.

BURNER CONTROL – No gas valve signal – Bad DSI unit.

IGNITION FAULT – No flame ignition detected thru all retries.

FLAME FAULT – Flame detected at ignition but failed later.

CLEAN LINT – Due to failure to clean out lint.

CHECK CONTROL BOARD FUSE #2 – 2 on Phase 7 board is
open.

EXHAUST PROBE FAULT / AXIAL – Indicated probe has failed.

ROTATION SENSOR – Rotation sensor or tumbler drive has
failed.

EXHAUST HI-TEMP – Overheating condition has occurred.

BURNER PURGE FAULT – Gas return signal before heat
output.

“S.A.F.E. System Disabled”

In Coin Mode hold “Pause” and “LO” keys down together.

OPEN / SHORTED THERMISTOR – Probe or probe circuit bad.

OPEN / SHORTED WATER VALVE – Water valve or circuit
bad.

WATER NOT CONNECTED – No water pressure at sol. valve.

“S.A.F.E. System (was) Activated”

Indicates the S.A.F.E. system is active or was active because
a fire was detected.  The buzzer sounds at a fast pace while
the system is active.

A service call to your local dealer is required to reset the
microprocessor controller (computer). Qualified personnel will
inspect the dryer and, if it is found to be safe for operation,
reset the control.

Содержание AD-35i

Страница 1: ...76 1 American Dryer Corporation 88 Currant Road Fall River MA 02720 4781 USA Telephone 1 508 678 9000 Fax 1 508 678 9447 e mail techsupport amdry com www adclaundry com To avoid errors and damage to the dryer please read these instructions carefully before attempting to install or operate ...

Страница 2: ...erosene oil paint or wax Items that have been spotted or soaked with vegetable or cooking oil constitute a fire hazard and should not be dried Do not dry mop heads Contaminations from wax or flammable solvents are a fire hazard Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this appliance Aqualified technician must be called if any high limit thermostat trips ...

Страница 3: ...113576 1 www adclaundry com 3 This Page Is Intentionally Left Blank ...

Страница 4: ... 22 9 24 9 Heat Rate Gas kW 20 5 36 6 39 6 Heat Rate Steam Normal Load Bhp 2 7 3 6 Steam Consumption kg hr 47 6 63 5 Electric Oven Size kW 6 7 13 5 18 5 20 4 22 0 18 5 20 4 22 0 Airborne Sound Level dB A 63 64 64 Tumbler Drive Motor kW 0 75 0 75 0 75 Blower Fan Motor kW 0 37 0 56 0 56 Net Weight Approximate kg 250 300 318 Shipping Weight Approximate kg 265 330 327 Cabinet Width A cm 81 0 87 6 99 1...

Страница 5: ...113576 1 www adclaundry com 5 ...

Страница 6: ... 50i 91 cm AD 80i 102 cm G 2 5 cm To allow control door to open H 2 5 cm I 1 5 mm J 1 5 mm Fresh Make Up Air Supply Requirements The dryer draws in air heats it passes it through the tumbler and exhausts it outside Adequate ventilation has to be provided to avoid the back flow of gases into the room from appliances burning fuels including open fires Insufficient fresh air supply could diminish dry...

Страница 7: ...45 in the direction of airflow The main duct diameter should increase before each individual duct is added Multiple Dryer Venting Through End Wall 3x 90 Turns AD 35i AD 50i AD 80i A m 15 80 12 10 B mm 152 203 203 203 Multiple Dryer Venting AD 35i AD 50i AD 80i A mm 152 203 203 B mm 810 876 991 Multiple Dryer Venting Through an End Wall C mm 203 254 254 D mm 254 356 356 E mm 305 406 406 F mm 356 45...

Страница 8: ...d to each dryer Failure to properly earth the dryer will void the warranty An external means of power removal disconnect device must be provided Each dryer should be connected to a properly sized and independently protected branch circuit The electric supply must match exactly what is specified on the dryer s rating plate data badge Electrical Connections The electrical input connections are made ...

Страница 9: ... 21 32 416V 3 13 5 22 32 AD 50i AD 80i Oven kW Amps 220V 1 18 5 89 0 125 230V 1 20 4 93 6 125 240V 1 22 0 96 6 125 220V 3 18 5 53 4 80 230V 3 20 4 56 1 80 240V 3 22 0 57 8 80 380V 3 18 5 34 7 50 400V 3 20 4 36 1 50 416V 3 22 0 37 2 50 NOTES ______________________________________________________ _____________________________________________________________ __________________________________________...

Страница 10: ... top of the dryer for this purpose The length and design of the restraint should be suitable to prevent strain on the gas line if the dryer is moved If the dryer is to be moved then the following steps must be taken Disconnect electrical power to the dryer Close all external gas supply shutoff valves Disconnect the gas supply line Remove the restraint from the dryer CE Approved Gas Types 2nd Famil...

Страница 11: ...Consult factory for elevations over 610m for correct burner injector size s 7 Instructions on how to convert the gas valve is included with the gas valve conversion kit see chart 8 Reverse step 4 to install the gas valve B with manifold D assembly 9 Open shutoff valve in the dryer s gas supply line 10 Test all connections for leaks 11 Connect gas valve wires 12 Continue electric power 13 Provide p...

Страница 12: ...supply connection into the main supply line must be made with a minimum 25 cm riser This will prevent any condensate from draining towards the dryer The steam supply line to the dryer must include a 30 cm riser along with a drip trap and check valve This will prevent any condensate from entering the steam coil Flexible hoses or couplings must be used The dryer vibrates slightly when operating whic...

Страница 13: ... 50i AD 80i 1 Steam Coil 2 Vacuum Breaker 3 Solenoid Valve 4 Flexible Hose or Coupling 5 Riser 6 Strainer 7 Manual Shutoff Valve 8 Drop 9 Dirt Leg 10 Drip Trap 11 Check Valve 12 Inverted Bucket Steam Trap 13 Return Main 14 Supply Main ...

Страница 14: ... with water and mild detergent solution non flammable Alternatively tumble a load of old garments that are wetted with water and mild detergent solution non flammable Preoperational Test A performance check is needed after the dryer is fully installed and before the dryer is ready for use Start the dryer refer to the Operating Instructions below Gas Dryers Check for flame ignition may need more th...

Страница 15: ...s from the factory you can FAX your order to ADC at 1 508 678 9447 or telephone our Parts Department at 1 508 678 9000 Please be prepared to provide the dryer model number serial number description of the part and the part number if known This dryer is equipped with two manually resettable high limit thermostats The burner high limit is located in the top center of the dryer behind the control doo...

Страница 16: ...orted LOW VOLTAGE FAULT Volt dropped below the operating value EE PROM FAULT Error in memory location Fault correction Enter the program mode by pressing the UP and STOP keys Press 4 and ENTER keys in password FAA Press UP ARROW Press enter to confirm reset of EE PROM Inputs Red L E D s All indications are with L E D lit ESTOP Indicates E STOP has been pressed GAS_V Indicates the gas valve is open...

Страница 17: ...g credit coin mode remaining time free mode MED Temps Exhaust left S A F E right Axial middle Axial dryer LO Tumbler RPM S A F E TEST Switch to program mode Press and hold the Pause key until prompted to press MED to open the water L C D Operating Messages When Display Reads Out of Order Pressing LO displays one of the causes listed below MODEL FAULT Wrong model selected at PL01 3rd position SAIL ...

Страница 18: ... shipments will be refused You will be notified if your warranty claim cannot be processed due to insufficient or missing information We must receive this information within 30 days otherwise the claim will be rejected and the part will be discarded For your convenience log the following information Date of Purchase ________________________________ Model Number __________________________________ R...

Отзывы: