Single Dryer Venting (50Hz)
Multiple Dryer (Common) Venting (50Hz)
If separate exhaust ducts are not possible then ducts from
multiple dryers may be channeled into a “common main duct.”
No more than four dryers should be commonly vented.
The individual ducts should enter the bottom or side of the main duct at an angle of not more than 45° in the direction of airflow. The
main duct diameter should increase before each individual duct is added.
Multiple Dryer Venting – Through End Wall (3x 90° Turns)
AD-35i
AD-50i
AD-80i
A (m)
15
80
12
10
B (mm)
152
203
203
203
Multiple Dryer Venting
AD-35i
AD-50i
AD-80i
A (mm)
152
203
203
B (mm)
810
876
991
Multiple Dryer Venting - Through an End Wall
C (mm)
203
254
254
D (mm)
254
356
356
E (mm)
305
406
406
F (mm)
356
457
457
L1+L2 (m)
50
30
25
Multiple Dryer Venting - Through Roof or Rear Wall
G (mm)
203
254
254
H (mm)
254
356
356
I (mm)
305
406
406
J (mm)
356
457
457
A1+A2+A3 (m)
35
12
10