Gas Type Conversion
This appliance must only operate with
the gas type indicated on the dryer’s
rating plate. If the appliance is
converted for use with a gas type other than the one indicated,
a new rating plate must be obtained from the manufacturer.
Burner conversion must be performed by qualified personnel
in accordance with national and local safety regulations.
The required conversion kit will depend on the gas type and
the country the dryer is installed in.
Parts Required for Conversion:
1. Rating Plate (Data Badge)
2. Injector (refer to Gas Specification Chart)
3. Gas valve conversion kit:
* Disables gas valve’s regulator. Adjust the gas supply pressure to the value
shown in the Gas Specification Chart.
Conversion Instructions
(Refer to figure)
1. Discontinue electrical power to the dryer.
2. Close shutoff valve in the dryer’s gas supply line.
3. Disconnect gas valve wiring (label wires first).
4. Disconnect the union (A) between the external shutoff and
the gas valve (B).
5. Remove screws (C) and remove the gas valve (B) with
manifold (D) assembly from the dryer.
6. Replace the main burner injector (E) with the correct injector
(see Gas Specification Chart).
* Consult factory for elevations over 610m for correct burner injector size(s).
7. Instructions on how to convert the gas valve is included
with the gas valve conversion kit (see chart).
8. Reverse step 4 to install the gas valve (B) with manifold
(D) assembly.
9. Open shutoff valve in the dryer’s gas supply line.
10. Test all connections for leaks.
11. Connect gas valve wires.
12. Continue electric power.
13. Provide proper gas pressure to the injector (see chart):
Gas supply pressure for categories I
2E+
and I
3+
must be
regulated in the dryer’s gas supply line.
All other gas categories require adjustment of the gas
valve’s internal regulator; instructions below.
14. Replace the original rating plate with the rating plate.
Burner Pressure Measure and Adjust
(Refer to figure)
1. Discontinue electrical power to the dryer.
2. Turn the gas valve’s switch (H) to “OFF” position.
Gas Valve Conversion Kit
Converting To
Gas Valve Kit
I
2E+
/ I
3+
* 140411
I
3B/P
/ I
3P
LP (AU/NZ)
140413
I
2H
/ I
2E(LL
) / I
2L
NG (AU/NZ)
140418
AU and NZ Gas Specifications
Gas
Characteristics
* ADG-35i
* ADG-50i
* ADG-80i
1 Injector
1 Injector
1 Injector
Gas
Type
Supply
Pressure
Burner
Pressure
Gas
Rate
Injector
Size
Burner
Pressure
Gas
Rate
Injector
Size
Burner
Pressure
Gas
Rate
Injector
Size
kPa
kPa
m
3
/H
mm
kPa
m
3
/H
mm
kPa
m
3
/H
mm
NG
1.7 - 3.2
0.90
1.98
3.988
0.83
3.40
5.220
0.83
3.77
5.613
LPG
2.75
2.67
0.62
2.438
2.50
1.07
3.264
2.50
1.13
3.454