4. Electrical Connections
A wiring diagram is located inside the control box for connection data.
If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord/pigtail
(wire size
must conform
to rating of dryer), or the dryer can be hard wired directly to the service breaker
panel. In both cases, a strain relief
must be
installed where the wiring enters the dryer.
IMPORTANT:
A separate protected circuit
must be
provided to each dryer.
a. Single-Phase (1ø) Wiring Connections/Hookup
The electrical input connections on
ALL
single-phase (1ø)
gas dryers are made into the rear service box located at the
upper left area of the dryer.
b. 3-Phase (3ø) Wiring Connections/Hookup
The electrical connections on
ALL
3-phase (3ø) gas dryers are made into the rear service box located
at the upper left area of the dryer. The electrical connections are made at the power distribution block
located in the service box. The ground connection is made to the copper lug, also provided in this box.
To gain access, the service box cover
must be
removed.
The neutral will only be used on 4-wire service. This is typical for 380-416V, 50 Hz.