F. ELECTRICAL INFORMATION
1. Electrical Requirements
It is your responsibility to have ALL electrical connections made by a properly licensed and competent
electrician to assure that the electrical installation is adequate and conforms to local and state regulations or
codes. In the absence of such codes, ALL electrical connections, materials, and workmanship must
conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST
EDITION, or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
IMPORTANT: Failure to comply with these codes or ordinances, or the requirements stipulated in this
manual, can result in personal injury or component failure.
NOTE: Component failure due to improper installation will VOID THE WARRANTY.
A separate circuit servicing each dryer must be provided. The dryer must be connected with copper wire
only. DO NOT use aluminum wire, which could cause a fire hazard.
NOTE: The use of aluminum wire will VOID THE WARRANTY.
2. Grounding
A ground (earth) connection must be provided and installed in accordance with state and local codes. In
the absence of these codes, grounding must conform to applicable requirements of the National Electrical
Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the Canadian Electrical Codes Parts 1 & 2
CSA C22.1-1990 or LATEST EDITION. The ground connection may be to a proven earth ground at the
location service panel.
For added personal safety, when possible, it is suggested that a separate ground wire (sized per local codes)
be connected from the ground connection of the dryer to a grounded cold water pipe. DO NOT ground to
a gas pipe or hot water pipe. The grounded cold water pipe must have metal to metal connection ALL
the way to electrical ground. If there are any nonmetallic interruptions, such as, a meter, pump, plastic,
rubber, or other insulating connectors, they must be jumped out with no. 4 copper wire and securely
clamped to bare metal at both ends.
IMPORTANT: For personal safety and proper operation, the dryer must be grounded.
3. Electrical Connections
A wire diagram is located on the inside of the control (service)
box for connection data.
a. Single-Phase (1ø) Hookup
The electrical input connections on ALL single-phase (1ø)
dryers are made into the junction box located at the upper
rear of the dryer. A separate circuit servicing each dryer
basket (tumbler) must be provided.