3. Make a complete operational check of ALL the operating controls to ensure that the timing is correct and
that the temperatures are set properly.
4. Make a complete operational check of ALL safety-related circuits (i.e., door switches, hi-limit thermostats,
sail switches, and basket [tumbler] safety thermostats, etc.).
NOTE: The sail switch can be checked for proper operation by opening the control door while the
dryer is running and the heating unit (burner) is active (on). The heating unit(s) should shut off
within a few seconds. If not, make the necessary adjustments.
5. Each basket (tumbler) should be operated through one (1) complete cycle to assure that no further
adjustments are necessary and that ALL components are functioning properly.
BASKET (TUMBLER) COATING
The basket (tumbler) is treated with a protective coating. We suggest dampening old garments or cloth material
with a solution of water and nonflammable mild detergent and tumbling them in the basket (tumbler) to remove
this coating.
6. Computer Programs and Selections
Each microprocessor controller (computer) has been preprogrammed by the factory with the most commonly
used program (parameter) selections. If microprocessor controller (computer) program changes are required,
refer to the computer programming manual, which was shipped with the dryer.
7. On models manufactured for 3-phase (3ø) electrical input voltage, check the electrical service phase
sequence. While the dryer is operating, check to see if the baskets (tumblers) are rotating in the clockwise
(CW) direction (when viewed from the front of the dryer). If the baskets (tumblers) rotate counterclockwise
(CCW), the phasing is incorrect. Reverse the two (2) leads at connection L1, L2, or L3 of the power
supply of the dryer.
J. SHUTDOWN INSTRUCTIONS
If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed:
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2. Discontinue the heat supply:
a. GAS MODELS...discontinue the gas supply.
1) SHUT OFF external gas supply shutoff valve (for both the top basket [tumbler] and the
bottom basket [tumbler] where the independent supply line for each basket [tumbler] is
used).
2) SHUT OFF internal gas supply shutoff valve located in the gas valve burner area (for both
the top basket [tumbler] and the bottom basket [tumbler]).