19

G.  GAS INFORMATION

It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas
plumbing installation is adequate and conforms to local and state regulations or codes.  In the absence of such
codes, ALL plumbing connections, materials, and workmanship must conform to the applicable requirements of
the National Fuel Gas Code ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes
CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST
EDITION.

In Australia, the fuel gas code is AS/NZS5601, local authority, gas, electricity, and any other relevant statutory
regulations.

IMPORTANT: Failure to comply with these codes or ordinances, and/or the requirements stipulated

in this manual, can result in personal injury and improper operation of the dryer.

The dryer and its individual shutoff valves must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).  The dryer must be isolated
from the gas supply piping system by closing its individual manual shutoff valve during any pressure test of the
gas supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).

IMPORTANT: Failure to isolate or disconnect the dryer from supply as noted could cause irreparable

damage to the gas valve, which will VOID THE WARRANTY

WARNING: FIRE OR EXPLOSION COULD RESULT.

1. Gas Supply

The gas dryer installation must meet the American National Standard...National Fuel Gas Code ANSI
Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural
Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION, as well as local codes and ordinances
and must be done by a qualified professional.

NOTE: Undersized gas piping will result in ignition problems, slow drying, increased use of energy, and

can create a safety hazard.

The dryer must be connected to the type of heat/gas indicated on the dryer label affixed to the left sidewall
area behind the middle access (control) door.  If this information does  not agree with the type of gas
available,  DO NOT operate the dryer.  Contact the reseller who sold the dryer or contact the ADC
factory.

IMPORTANT: Any burner changes or conversions must be made by a qualified professional.

The input ratings shown on the dryer data label are for elevations up to 2,000 feet (610 meters), unless
elevation requirements of over 2,000 feet (610 meters) were specified at the time the dryer order was
placed with the factory.  The adjustment or conversion of dryers in the field for elevations over 2,000 feet
(610 meters) is made by changing each burner orifice.  If this conversion is necessary, contact the reseller
who sold the dryer or contact the ADC factory.

IMPORTANT: THIS GAS DRYER IS NOT PROVIDED WITH AN INTERNAL GAS SUPPLY

SHUTOFF AND AN EXTERNAL GAS SUPPLY SHUTOFF MUST BE
PROVIDED.

Содержание AD-236

Страница 1: ...on et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz WARNING For your safety the information in this manual must be followed to mini...

Страница 2: ...____________________________________________________________ Serial Number s ________________________________________________________________________________________ __________________________________...

Страница 3: ...emicals known to the State of California to cause cancer birth defects and other reproductive harm In the State of Massachusetts the following installation instructions apply Installations and repairs...

Страница 4: ...en 40 F 4 44 C and 130 F 54 44 C FORYOUR SAFETY DONOTDRYMOPHEADSINTHEDRYER DONOTUSEDRYERINTHEPRESENCEOFDRYCLEANINGFUMES WARNING UNDER NO CIRCUMSTANCES should the dryer door switches lint drawer switch...

Страница 5: ...10 D FreshAirSupplyRequirements 10 E ExhaustRequirements 12 F ElectricalInformation 16 G GasInformation 19 H Preparation For Operation Start Up 23 I PreoperationalTest 23 J ShutdownInstructions 25 SE...

Страница 6: ...ustments 32 C Lubrication 32 SECTION VIII DATA LABEL INFORMATION 33 A Data Label 33 SECTION IX TROUBLESHOOTING 35 SECTION X PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 40 SECTION XI BURNE...

Страница 7: ...should be accepted but the number received and the number refused must be noted on the receipt 4 If you determine that the dryer was damaged after the trucker has left your location you should call t...

Страница 8: ...lding or area of ALL occupants e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions f If you cannot reach your gas supplier call the fire department 5 In...

Страница 9: ...be used in the presence of dry cleaning solvents or fumes 13 Remove articles from the dryer as soon as the drying cycle has been completed WARNING Articlesleftinthedryerafterthedryingandcoolingcyclesh...

Страница 10: ...IMATE SHIPPING WEIGHT 900 lb 408 2 kg AIRFLOW PER POCKET 60 Hz 400 cfm 11 33 cmm 50 Hz 333 cfm 9 44 cmm HEAT INPUT PER POCKET 80 000 Btu hr 20 160 kcal hr EXHAUST CONNECTION DIAMETER 8 20 32 cm COMPRE...

Страница 11: ...113047 21 www adclaundry com 7 SPECIFICATIONS ADG 236 GAS NOTE ADC reserves the right to make changes in specifications at any time without notice or obligation...

Страница 12: ...nd put in a safe place yet made accessiblebecausethey willbe neededthroughoutvariousphasesintheinstallationofthe dryer Dryers are shipped with a coin box and coin box faceplate ONLY The coin box lock...

Страница 13: ...must be provided as noted in this manual refer to Fresh Air Supply Requirements in Section D 5 Clearance provisions must be made from combustible construction as noted in this manual refer to Dryer E...

Страница 14: ...illustration on the previous page for details NOTE Airconsiderationsareimportantforproperandefficientoperation IMPORTANT Even though a minimum of only 12 inches 30 48 cm is required 18 inches 45 72 c...

Страница 15: ...ces must be made for remote or constricting passageways or where dryers are located at excessive altitudes or predominantly low pressure areas IMPORTANT Make up air must be provided from a source free...

Страница 16: ...rk should be laid out in such a way that the ductwork travels as directly as possible to the outdoors with as few turns as possible It is suggested that the use of 90 turns be avoided use 30 and or 45...

Страница 17: ...alled at strategic points in the exhaust ductwork for periodic inspection and cleaning of lint from the ductwork NOTE When the exhaust ductwork passes through a wall ceiling or roof made of combustibl...

Страница 18: ...extent Maximum proportional ductwork runs cannot exceed 20 feet 6 1 meters more than the original limitations of 20 feet 6 1 meters with one 1 elbow Whentheductworkapproachesthemaximumlimitsasnotedin...

Страница 19: ...ard should be installed where the exhaust exits the building If the exhaust ductwork travels vertically up through the roof it should be protected from the weather by using a 180 turn to point the ope...

Страница 20: ...h state and local codes In the absence of these codes grounding must conform to applicable requirements of the National Electrical Code ANSI NFPA NO 70 LATEST EDITION or in Canada the Canadian Electri...

Страница 21: ...ground Single phase 1 power for the control circuit and for any single phase 1 motor if present is done internally to the dryer No single phase 1 input connection is required on a 3 phase 3 dryer a 3...

Страница 22: ...GE PHASE WIRE SERVICE APPROX AMP DRAW CIRCUIT BREAKER 60 Hz 50 Hz 120 1 2 8 7 15 208 1 2 5 2 15 240 1 2 4 8 4 7 15 208 3 3 3 15 240 3 3 3 2 15 Check your national and local codes for breaker and wire...

Страница 23: ...d cause irreparable damage to the gas valve which willVOIDTHEWARRANTY WARNING FIRE OR EXPLOSION COULD RESULT 1 Gas Supply The gas dryer installation must meet the American National Standard National F...

Страница 24: ...at each gas valve pressure tap must be a consistent 10 5 inches 26 1 mb water column There is no regulator or regulation provided in an L P dryer The water column pressure must be regulated at the sou...

Страница 25: ...tpressure whichwillresultin erraticoperationoftheburnerignitionsystem Consistent gas pressure is essential at ALL gas connections It is recommended that a 3 4 inch 19 05 mm pipe loop be installed in t...

Страница 26: ...22 American Dryer Corp 113047 21...

Страница 27: ...closed and secured in place 8 Be sure the lint drawer is securely in place 9 Rotate the basket tumbler drum by hand to be sure it moves freely 10 Check bolts nuts screws terminals and fittings for se...

Страница 28: ...START 3 Repeat above procedure for the other basket tumbler 2 Heat Circuit Operational Test a When a gas dryer is first started during initial start up it has a tendency not to ignite on the first ign...

Страница 29: ...ter has been preprogrammed by the factory with the most commonly used program parameter selections If microprocessor controller computer program changes are required refer to the computer programming...

Страница 30: ...etermined start the dryer by pressing that setting key 3 The dryer will now start and the L E D display will read the setting and the time vended i e LO 10 4 The cycle time will count down until the d...

Страница 31: ...__ ___________________________________________________________________________________________________________________________ _________________________________________________________________________...

Страница 32: ...model numberandserialnumbersothatyourinquiryishandledinanexpeditiousmanner B PARTS 1 Replacement parts should be purchased from the reseller from whom the ADC equipment was purchased If the reseller...

Страница 33: ...ller from whom you purchased the equipment and request a dryer warranty form If the reseller cannot be contacted or is unknown warranty information can be obtained from the factory by contacting the A...

Страница 34: ...are not damaged in transit Damage claims are the responsibility of the shipper IMPORTANT No replacements credits or refunds will be issued for merchandise damaged in transit 5 ALL returns should be sh...

Страница 35: ...D OTHER FLAMMABLE VAPORSAND LIQUIDS NOTE Suggested time intervals shown are for average usage which is considered six 6 to eight 8 operational running hoursperday IMPORTANT Dryer produces combustible...

Страница 36: ...void using harsh abrasives Aproduct intended for the cleaningofappliancesisrecommended B ADJUSTMENTS 7 DAYS AFTER INSTALLATION AND EVERY 6 MONTHS THEREAFTER Inspect bolts nuts screws bearing setscrews...

Страница 37: ...rvice parts information from ADC This information is on the data label that is located on the left sidewall area behind the middle access control door When contacting ADC please have the model number...

Страница 38: ...t for your particular dryer gas either natural gas or L P gas electric or steam 4 Heat Input For Gas Dryers This describes the heat input in British thermal units per hour Btu hr or kilowatts kW 5 Ori...

Страница 39: ...laced The information provided should not be misconstrued as a handbook for use by an untrained person in making repairs WARNING ALL SERVICEAND TROUBLESHOOTING SHOULD BE PERFORMED BYA QUALIFIED PROFES...

Страница 40: ...o the normal FILL mode NOTE Once the microprocessor controller computer detects a problem it updates every 30 seconds so that if a problem was a loose connection in this circuit which corrected itself...

Страница 41: ...ion sensor and the microprocessor controller computer I Microprocessorcontroller computer willnotacceptany oronlyacceptcertainkeypadentries 1 Failed keypad label assembly 2 Failed microprocessor contr...

Страница 42: ...Ignition DSI module burner control 5 Failed DSI ignitor and or flame probe assembly N No heat ignitor sparks but there is no flame at burner 1 DSI ignitor probe is out of adjustment a Reposition ignit...

Страница 43: ...naccurate 10 Lint accumulation in location exhaust system Q Condensation on main door glass 1 Too long undersized or improperly installed ductwork 2 Exhaust back draft damper is stuck closed or partia...

Страница 44: ...controller computer board reestablish power to the dryer b Start the drying cycle c Verify that the motors and the heat indicator dots in the microprocessor controller computer light emitting diode L...

Страница 45: ...n Start the drying cycle When the gas burner ignites within the chosen trial for ignitiontime 6 seconds theflamesensor detects gas burner flame and signals the DSI module to keep the gas valve open as...

Страница 46: ...mately 8 seconds The burner flame should now be established e With the burner flame on remove the flame sensor wire from the FS terminal of the DSI module f The burner flame must shut off and the igni...

Страница 47: ...mbler hi limit thermostat and will start or continue through the drying cycle with no heat The applicable open tripped manual reset hi limit must be reset manually This hi temperature condition may be...