S.A.F.E. SYSTEM IN ACTION
The exclusive Sensor Activated Fire Extinguishing (S.A.F.E.) System will extinguish fires that may start in the drying
tumbler. A series of sensors positioned throughout the tumbler and interfaced with the microprocessor will trigger the
S.A.F.E. system water jet(s) to quickly extinguish the flames. The water jet(s) remain on for 2 minutes and will
automatically activate again if a fire condition remains or reignites. While the water jet(s) are activated, the tumbler
will jog to move the water throughout the load. The microprocessor will display that the system was activated and will
continue to display until the dryer is attended to.
We have tried to make this manual as complete as possible and hope you will find it useful. ADC reserves the right to
make changes from time to time, without notice or obligation, in prices, specifications, colors, and material, and to
change or discontinue models.
BEFORE YOU START!
CHECK LOCAL CODES AND PERMITS
Call your local water company or the proper municipal authority for information regarding local codes.
IMPORTANT: It is your responsibility to have ALL plumbing connections made by a qualified professional
to assure that the plumbing installation is adequate and conforms to local, state, and federal
regulations or codes.
IMPORTANT: It is the installer’s or owner’s responsibility to see that the necessary or required water,
water pressure, pipe size, or connections are provided. Manufacturer assumes no
responsibility if the Sensor Activated Fire Extinguishing (S.A.F.E.) System is not connected,
installed, or maintained properly.
WARNING: Water must be supplied to S.A.F.E. system or dryer will not operate.
INSTALLATION
1. Requirements
The connection point to the electric water solenoid valve is a 1/2” M.P.T., the S.A.F.E. system must be supplied
with a minimum water pipe size of 1/2-inch and be provided with 40 PSI (2.75 bar) and a maximum of 100 PSI
(6.89 bar) of pressure. For use of optional manual bypass, a second source with the same piping and pressure
requirements is required.
Flexible 1/2 feeds must be provided to avoid damage to electric water solenoid valve by vibration (for non-tilt
models only).
Содержание AD-210
Страница 15: ...113549 8 www adclaundry com 11 1 Reassembly Instructions For Gas Dryer Shipped In Two 2 Pieces ...
Страница 17: ...113549 8 www adclaundry com 13 2 Reassembly Instructions For Steam Dryer Shipped In Two 2 Pieces ...
Страница 23: ...113549 8 www adclaundry com 19 210 STEAM DRYER 6 500 CFM 184 CMM HORIZONTALDRYERVENTING ...
Страница 66: ...ADC Part No 113549 8 04 08 22 ...