56
American Dryer Corporation
113549 - 8
IMPORTANT: Flexible supply line/coupling must be used. Solenoid valve failure due to hard plumbing
connections WILL VOID WARRANTY (for non-tilt models only).
If the rear area of the dryer, or the water supply is located in an area where it will be exposed to cold/freezing
temperatures, provisions must be made to protect these water lines from freezing.
WARNING: If the water in the supply line or water solenoid valve freezes, the S.A.F.E. system will be
INOPERATIVE!!
IMPORTANT: Appliance is to be connected to the water mains using a new hose set and the old hose set
should not be reused.
2. Water Connections:
The water connection is made to the 3/4” F.P.T. bushing of the electric water solenoid valve located at the rear
upper left area of the dryer. The water solenoid valve has a 1/2” M.P.T. connection and a 1/2” bushing is supplied
to provide the minimum 1/2-inch supply (feed) line. Flexible supply line/coupling must be used in effort to avoid
damage to electric water solenoid valve.
WARNING: Water must be supplied to sensor activated fire extinguishing (S.A.F.E.) system or dryer will
not operate.
IMPORTANT: Flexible supply line/coupling must be used. Solenoid valve failure due to hard plumbing
connections WILL VOID WARRANTY. It is recommended that a filter or strainer be
installed in the water supply line.
Typical water supply...
Содержание AD-210
Страница 15: ...113549 8 www adclaundry com 11 1 Reassembly Instructions For Gas Dryer Shipped In Two 2 Pieces ...
Страница 17: ...113549 8 www adclaundry com 13 2 Reassembly Instructions For Steam Dryer Shipped In Two 2 Pieces ...
Страница 23: ...113549 8 www adclaundry com 19 210 STEAM DRYER 6 500 CFM 184 CMM HORIZONTALDRYERVENTING ...
Страница 66: ...ADC Part No 113549 8 04 08 22 ...