background image

  

Installation and Operating Manual 

 

Advantage DK  

ADV-1000 

 

ADV-1000i (intercom)

 

Digital Access Control Station

 

 
 
 

 

 

 
 
 
 
 
 
 

This product available from:
D.A.D.S., Inc.
1-800-442-9925
US & Canada 

 

 
 

 

 
 
 
 

Содержание ADV-1000

Страница 1: ...Installation and Operating Manual Advantage DK ADV 1000 ADV 1000i intercom Digital Access Control Station This product available from D A D S Inc 1 800 442 9925 US Canada ...

Страница 2: ...OOD TONES AND ERROR TONES 11 PROGRAMMING THE DK UNIT 12 Program Relay A Access Codes Sub Mode 1 13 Delete Individual Access Codes Sub Mode 2 14 Change the Master Code Sub Mode 3 14 Set Sleep Code Sub Mode 4 15 Set Latch Code Sub Mode 5 16 Set Relay Output Times Sub Mode 6 16 Program Relay B Access Codes Sub Mode 7 16 Enable or Disable the Three Strikes You re Out Sub Mode 8 17 Event Input Sub Mode...

Страница 3: ...ase Contact the original dealer or installer of the product and return your AAS product along with the receipt to them If you have problems locating the dealer or installer contact American Access Systems at 303 799 9757 and we will direct you to an AAS authorized dealer or distributor If you ship your AAS product you must prepay all shipping charges We suggest that you retain your original packin...

Страница 4: ...ccess Systems AAS QTY Item 1 Advantage DK Control Station w 2 keys 4 20 X carriage bolts 4 20 hex nuts TOOLS NEEDED FOR BASIC INSTALLATION Wire nuts or appropriate terminals connectors Wire strippers Wire cutters 3 8 drive ratchet 6 extension 7 16 socket Digital or Analog multi meter Technical Customer Support 1 303 799 9757 or techsupport americanaccess com ...

Страница 5: ...Page 5 American Access Systems ...

Страница 6: ...e 1 programmable 4 digit Latch Code Master user ability to program up to 1000 4 digit access codes which can be assigned to 1 of 2 relays A programmable Three Strikes You re Out feature which disables the unit for approximately 90 seconds if three incorrect Access Codes are entered during a 90 second time period Two relays programmable from to 99 seconds incorporating both normally open N O and no...

Страница 7: ...ypad face open place the unit against the pedestal flange insert the four carriage bolts from the back of the unit and tighten the hex nuts from the inside Wrench tighten the hex nuts securely Do not over tighten SYSTEM CONNECTIONS An Operator Wiring Diagram and a Door Strike Mag Lock wiring diagram for the Advantage DK are shown on page 5 The most common installation connects the DK unit to a Gat...

Страница 8: ...olts AC or DC GREEN EARTH GROUND ONLY RELAY A PRIMARY CONTROL COLOR CODES BROWN RELAY A COMMON ORANGE RELAY A NORMALLY OPEN N O BLUE RELAY A NORMALLY CLOSED N C RELAY B SECONDARY CONTROL COLOR CODES Use if controlling a second device GRAY RELAY B COMMON VIOLET RELAY B NORMALLY OPEN N O YELLOW RELAY B NORMALLY CLOSED N C ...

Страница 9: ...s page 5 c If you interface with a secondary device connect the unit s secondary relay control leads to the secondary device Refer to the Wiring Diagrams page 5 4 Connect the Green lead to Earth Ground 5 Before supplying power to the unit refer to the appropriate wiring diagram to double check all connections When you are sure you have the unit wired correctly apply power to the unit a If this is ...

Страница 10: ...tion Code used to program Access Codes into the DK unit The factory default master code is 1 2 5 1 The Owner Administrator enters the Master Code to program the Access Codes others will use to gain entry to the area controlled by the unit It is recommended that the Master Code be re programmed to a four digit code of your choice Remember to make a note of the new Master Code It is the password to ...

Страница 11: ...ng the keypad If the correct Master Code is entered the unit will reply with a GOOD TONE and the Yellow LED will illuminate In the Program Mode you have approximately 30 seconds between key presses If the 30 second time period is exceeded during programming the unit will automatically exit the Programming Mode No damage is done to the programming Simply complete the programming steps again NOTE 1 ...

Страница 12: ...OOD TONE will sound You can now enter any of ten programming SUB MODES described below SUB MODE NUMBER CODE DESCRIPTION 1 Program an Access Code s Relay A 2 Delete an Access Code 3 Change Master Code 4 Set Sleep Code 5 Set Latch Code 6 Set Relay Output Times 7 Program an Access Code s Relay B 8 Enable Disable the 3 Strikes You re Out Feature 9 Program Event Input 0 Erase Memory ...

Страница 13: ...d you must select another code If you make a mistake during entry press the star Å key then re enter the code When a new code is accepted the unit will sound a GOOD TONE Continue to enter codes until you are finished When you are done press the pound key to exit the programming mode NOTES You will automatically be exited from the programming mode IF The memory reaches capacity The memory is full y...

Страница 14: ...You can delete any Access or Function code that you wish with the exception of the MASTER CODE If the code you want to delete is not found in memory the unit will respond with an ERROR TONE and wait for another code to be entered A GOOD TONE will sound once the code has been found and deleted You may continue deleting codes until you are done then press the pound key to exit the programming mode C...

Страница 15: ...h relays in parallel managers may be assigned Relay B codes and still gain access While in the SLEEP MODE the yellow and red LED s will flash every 3 seconds To initialize the system back to normal simply re enter the Sleep Code Should you lose or forget the Sleep Code and the unit is in the sleep mode you must complete a Master Reset See the instructions on pages 20 and 21 To program or change th...

Страница 16: ...e that is not already in use If you make an entry error simply press the star Å key and enter the number you wish When a new Latch Code is accepted you will hear a GOOD TONE Press the pound key to exit the programming mode Now when the new Latch Code is entered the RED LED will light and the gate will hold open When the new Latch Code is entered a second time the RED LED will go off and the gate w...

Страница 17: ...orized user The unit will then continue in full lockout mode for another 60 seconds even after the alarm ends After 90 seconds the unit will revert to the IDLE MODE and will operate normally To toggle the Three Strikes You re Out feature on or off Enter the current Master Code Unit will sound a GOOD TONE Press the numeral 8 and the unit will respond with either one or two tones A single tone indic...

Страница 18: ...mmed 4 separate ways 1 To program Event Input as Remote Inactive Enter the MASTER CODE Unit will sound a GOOD TONE Enter the numeral 9 Unit will sound the Current Mode Unit will sound a GOOD TONE Enter the numeral 1 Unit will sound a GOOD TONE DEFINE 1 2 3 2 To program the Event Input as an Arming Circuit Enter the MASTER CODE Unit will sound a GOOD TONE Enter the numeral 9 Unit will sound the Cur...

Страница 19: ...l Codes Sub Mode 0 Caution This is a destructive Programming Mode Completing the following steps will erase all Access Codes except for the factory default Master Code 1 2 5 1 Use with Caution DETAILS This Sub Mode should rarely be used unless you want to completely erase all Access Codes entered This action will not change the Master Code To erase all Access Codes and Function Codes Enter the Mas...

Страница 20: ...to the 1 2 5 1 Should be used if the unit is in the Latch or Sleep Mode and the Latch or Sleep code is lost or forgotten When a Master Reset is performed Access Codes and Functions Codes are retained in memory and the unit does not require complete reprogramming Unit Reset Should only be used if the Advantage DK is to be completely reset back to factory default settings ALL ACCESS and FUNCTION COD...

Страница 21: ...re lost when performing a Unit Reset Follow these steps exactly If you make an error an ERROR will occur a low pitch ERROR tone will sound and you will need to start over from Step 1 1 Open the faceplate 2 Disconnect the power from the unit by gently pulling the wire harness away from the board Make sure to note the orientation of the connector 3 Press and hold down the RESET button and reconnect ...

Страница 22: ...Page 22 American Access Systems Event Input ...

Страница 23: ...erriding the keypad when it is in a latch mode Contact Gate Operator manufacturer When I enter a valid Access Code the gate does not open Locate the two wires attached to the Brown and Orange wires on the main wire harness then touch them together If the gate does not open check wiring or the connection terminals on gate operator If the gate opens contact American Access Systems I connected the tw...

Страница 24: ...____ _______________________________________________ _______________________________________________ _______________________________________________ _______________________________________________ _______________________________________________ _______________________________________________ _______________________________________________ _______________________________________________ ___________...