Page 16
© American Access Systems
Set Latch Code -- Sub-Mode 5
DETAILS: The Latch Code toggles the state of the main relay (A) of the circuit board. The red LED will
remain lit while the relay is in the latched position. The latch code is useful in applications where the gate
is desired to hold open. If the operator's close circuit is controlled by loops, timers, etc., they will be
overridden by the latched state of the relay and the gate will hold open. An "OPEN-OVERRIDE" circuit
must exist in the
operator in order to utilize this function. If your gate cycles when this code is entered,
your operator is not set up to utilize this function. Your local dealer or distributor should be able to assist
you if you have any specific questions.
To program or change the Latch Code:
-
Enter the current Master Code
-
Press the numeral 5
-
Enter a new Latch Code (If you hear an ERROR TONE, select another code that is not already in
use
-
If you make an entry error, simply press the star (
Å
) key and enter the number you wish
-
When a new Latch Code is accepted you will hear a GOOD TONE
-
Press the pound
(#)
key to exit the programming mode
-
Now, when the new
Latch Code
is entered, the RED LED will light and the gate will hold open
-
When the new
Latch Code
is entered a second time the RED LED will go off and the gate will
close
NOTE
:
On gates with a closing timer, the “TIMED DURATION” begins when the Latch Code is released.
Set Relay Output Times -- Sub-Mode 6
To set or change a Relay Output Time:
-
Enter the current Master Code
-
Press the numeral 6
-
Enter the Relay numeral (1 = Relay A; 2 = Relay B)
-
Enter the desired Relay Output Time in seconds (i.e., enter 6 0 for 60 seconds)
-
Press the pound
(#)
key to exit the programming mode
Program Relay “B” Access Codes -- Sub-Mode 7
To program Relay “B” Access Codes:
-
Enter the current Master Code
-
Press the numeral 7
-
Enter a new Relay B Access Code (If you hear an ERROR TONE, select another code that is not
already in use)
-
When a new Latch Code is accepted you will hear a GOOD TONE