Page 21
© American Access Systems
MASTER RESET
Follow these steps exactly. If you make an error, an ERROR will occur (you will hear a low ERROR tone)
and you will need to start over from Step 1.
1.
Open the unit face plate using the key provided.
2.
Disconnect power from the unit by gently pulling the wire harness connector away from the board.
Make sure to note the orientation of the connector.
3.
Press and hold down the RESET button and reconnect power to the board by gently sliding the
harness connector back into place on the circuit board, then release the RESET button. (See
location Board Layout diagram, page )
4.
The Master Code is now reset to the factory default (1 2 5 1)
5.
Close the face plate.
6.
Program a new Master Code if you choose to do so. Be sure to make a note of the new Master
Code.
UNIT RESET
NOTE: ALL ACCESS CODES and FUNCTION CODES are lost when performing a Unit Reset.
Follow these steps exactly. If you make an error, an ERROR will occur (a low-pitch ERROR tone will
sound) and you will need to start over from Step 1.
1.
Open the faceplate.
2.
Disconnect the power from the unit by gently pulling the wire harness away from the board. Make
sure to note the orientation of the connector.
3.
Press and hold down the RESET button and reconnect power to the board by gently sliding the
harness connector back into place on the circuit board, then release the RESET button. (See
location Board Layout diagram, page 22)
4.
Enter
(#)
(
Å
)
(#)
(Pound, Star, Pound)
5.
The unit will respond with a GOOD TONE
6.
Enter the MASTER CODE (1 2 5 1) from the keypad. The unit will flash the LED's several times and
then go into an endless cycle of tones.
7.
While the cycle of tones continues, disconnect and then immediately reconnect power to the unit
using the circuit board harness connector. The unit will then go through the
"First Time Power Up"
sequence. (See page 5).
8.
The DK is now completely reset. All programming is erased.
Содержание ADV-1000
Страница 5: ...Page 5 American Access Systems ...
Страница 22: ...Page 22 American Access Systems Event Input ...