A6 OPERATING INSTRUCTIONS
05/12/16
4211-146
Page 9 of 11
Available Languages in the A6
Czech
Danish
German
English
Spanish
Dutch
Norwegian
Polish
Portuguese
Russian
Slavic
Finnish
Swedish
Warm Start: Is It Installed?
If you enable Warm Start on the A6 and you get a
steam tank temperature error when you try to turn on
Warm Start for the first time (
see
Turning Things On
and Off
on page 2), you’ll need to remove the cover
from your steamer and see if the Warm Start option
is installed.
If warm start is installed, you’ll see a temperature
sensor on the side of the steam tank which connects
through a tube to the steamer’s circuit board.
If Warm Start is installed and you still get a sensor
error, first make sure the sensor is connected to both
pins on the steamer board (between the cable jacks
and the level probe wires).
If it is connected, contact
Support for further assistance.