A6 OPERATING INSTRUCTIONS
05/12/16
4211-146
Page 5 of 11
Warm Start On
Limits menus
To set the maximum allowed bath temperature, select
Bath temperature
. This lets you
limit the temperature anyone can set the bath to (no more than 125°F by default). For
instance, if you have someone in the family who is sensitive to heat, you may set the
limit to 115°F so they cannot accidentally set the bath too hot. They can still adjust the
bath temperature, just with a lower maximum setting.
If you want to prevent the steam bath from being used during certain hours, say during
the day while you’re not at home or from 10:00 pm to 7:00 am for a hotel’s quiet time,
use the
Not allowed start
setting to set the time period.
If you have water problems which might prevent you from having water available for the
steamer, set the
Max water fill time
to a reasonable time limit. If water pressure is too
low, you may need a longer time. If your water supply is normally good, you may be
able to set it to 2 or 3 minutes. Default is 6 minutes.
If it takes longer than the fill time setting to reach normal operating levels in the steam, the system will
show you an error and shut down to prevent damage to the steamer.
And remember, you must have at
least 20 psi (138 kPa) water pressure for proper operation.
Additional settings menus
Warm Start
is an option which keeps the water in the steam tank warm so the steamer
produces steam more quickly after the bath is turned on. If you do not have Warm Start
installed, select warm start and move the slider to disable it.
If Warm Start is installed, you may adjust the temperature up from the 176°F default to
speed up steam production even more. If you do turn up the Warm Start temperature,
watch for steam from the steam outlet while the bath is off. If you see steam while only
Warm Start is running, turn down the temperature a few degrees and repeat until the
steaming stops.
If you have a vent fan connected to the steamer’s FAN option terminal block, select
Fan
to set up how it will operate. Turn on Automatic to have the fan run after the bath. The
fan will run 20 minutes by default but may be set from 1 minute to 3 hours by changing
the Running Time setting. The fan may also be turned on or off manually while in this
menu.
Next scroll down further for the System menu section.
System menus
Options
and
WiFi
will be covered in their own sections.
Use the
Cleanup note
settings to turn on/off a reminder which tells you when it is time
to clean the tanks, such as for decalcification when you have hard water. You can also
set the number of operating hours before the reminder appears.
In this menu, you also can choose to see reminders that the tank should be emptied
after a bath. If you do not have an automatic electronic drain valve, you should drain
the tank periodically to keep it clean. How often depends on you water quality. If you
cannot get to your steamer’s manual drain valve easily, we recommended turning off
the Tank Empty Notes so you don’t see the reminders.
The rest of this menu is
for service use and should be left as is.
Options
Warm Start Off