20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
SMD34K User Manual
H
OMING
AN
SMD34K
53
Homing Profiles
The CW Find Home command is used in all of these examples. The CCW Find Home com-
mand will generate the same profiles in the opposite direction.
Home Input Only Profile
Figure R4.1 below shows the move profile generated by a CW Find Home command when you use the Home
Input without the Backplane_Proximity_Bit.
Figure R4.1 Home Input Profile
1) Acceleration from the configured Starting Speed to the Programmed Speed
2) Run at the Programmed Speed until the Home Input activates
3) Deceleration to the Starting Speed and stop, followed by a two second delay.
4) Acceleration to the Programmed Speed opposite to the requested direction.
5) Run opposite the requested direction until the Home Input transitions from Active to Inactive
6) Deceleration to the Starting Speed and stop, followed by a two second delay.
7) Return to the Home Input at the configured Starting Speed. Stop when the Home Input transitions
from inactive to active.
If the Home Input is active when the command is issued, the move profile begins at step 5
above.
(CW)
(CCW)
S
P
E
E
D
POSITION
Home Limit
Switch
Содержание SMD34K
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S280 ...
Страница 6: ...TABLE OF CONTENTS SMD34K User Manual ADVANCED MICRO CONTROLS INC 6 Notes ...
Страница 50: ...CALCULATING MOVE PROFILES SMD34K User Manual ADVANCED MICRO CONTROLS INC 50 Notes ...
Страница 62: ...CONFIGURATION DATA FORMAT SMD34K User Manual ADVANCED MICRO CONTROLS INC 62 Notes ...
Страница 80: ...COMMAND DATA FORMAT SMD34K User Manual ADVANCED MICRO CONTROLS INC 80 Notes ...
Страница 100: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC ...