SMD34K S
PECIFICATIONS
SMD34K User Manual
ADVANCED MICRO CONTROLS INC.
18
Status LED’s
Each SMD34K has two status LED’s that shows the status of the
functional status of the device. As shown in figure R1.3, these
LEDs are located on the rear cover. They are named “RUN” and
“ERR”. Two additional LEDs are located on the near cover
between the two network connectors. These two LEDs are the
LINK/ACT LEDs for the Ethernet ports. They are on when there is
a physical connection between the device and the previous or next
device in the network. They blink when data is being transmitted
over the network.
Run LED
The green RUN LED indicates the logical state of the device.
Table R1.3 Module RUN LED States
Error LED
The ERR LED location houses a red/green LED. The red LED indicates an error state in the EtherCAT
protocol. The green LED indicates the operational state of the SMD34K itself. Both LEDs can be on
simultaneously.
Table R1.4 Red ERR LED States
Table R1.5 Green ERR LED States
LED State
Description
Off
Device in the EtherCAT Init state
Fast Blink
(4 Hz)
Device in the EtherCAT Pre-Operational
(Pre-Op) state
Slow Blink
(1 Hz)
Device in the EtherCAT Safe-Operational
(Safe-Op) state
Steady Green
Device in the EtherCAT Operational (Op)
state.
Red LED State
Description
Off
No errors in device operation
Single blink
200 ms ON / 1 s OFF
Problems with synchronization such as with the Distrib-
uted Clock (DC) PLL.
Double Blink
200 ms Pulses / 1 s between
SYNC manager watchdog timeout. The master has not
updated the output data in the configured time interval. The
SMD34K has switched to the Safe-OP state.
Slow Blink
(1 Hz)
All other issues, such as cable disconnect. The SMD34K
has switched to the Safe-OP state.
Green LED State
Description
Solid Green
Device in the EtherCAT Init state
Very Slow Blink Green
‡
(0.5 Hz)
Driver Fault (Overtemperature fault, etc.)
Slow Blink Green
‡
(1 Hz)
Unsuccessful write to flash memory
Fast Blink Green
‡
(4 Hz)
Successful write to flash memory
Figure R1.3 Rear Cover Status LED’s
POWER
24 to 80 Vdc
DIGITAL INPUTS
5 to 24 Vdc
ERR
RUN
OUT
IN
Содержание SMD34K
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S280 ...
Страница 6: ...TABLE OF CONTENTS SMD34K User Manual ADVANCED MICRO CONTROLS INC 6 Notes ...
Страница 50: ...CALCULATING MOVE PROFILES SMD34K User Manual ADVANCED MICRO CONTROLS INC 50 Notes ...
Страница 62: ...CONFIGURATION DATA FORMAT SMD34K User Manual ADVANCED MICRO CONTROLS INC 62 Notes ...
Страница 80: ...COMMAND DATA FORMAT SMD34K User Manual ADVANCED MICRO CONTROLS INC 80 Notes ...
Страница 100: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC ...