20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
RBE2-8 User Manual
RBE2-8 I
NTRODUCTION
11
Compatible Relays
The RBE2-8 was designed for compatibility with the following AC and DC Relays:
Sensata-Crydom MCXE240D5, MP120D3, MP240D3, and MP240D4 AC relays
Opto22 MP120D4, and MP240D4 AC relays
Sensata-Crydom MPDCD3 and MPDCD3-B DC Relays
Opto22 DC60MP and DC200MP DC Relays
Relays from other manufacturers that have identical physical dimensions and use 24Vdc as the control volt-
age, should also be compatible with the RBE2-8. Contact AMCI for assistance if required.
AC Relay Specifications
Table R1.6 AC Relay Specifications
DC Relay Specifications
Table R1.7 DC Relay Specifications
Crydom
Crydom
Crydom
Crydom
MP120D3
MP240D3
MP240D4
MCXE240D5
Control Voltage (Vdc)
3 - 32
3 - 32
3 - 32
15 - 32
Typical Control Current (mA)
23
23
23
15
Load Voltage (Vrms) 47-63 Hz
12 - 140
24 - 280
24 - 280
12 - 280
Transient Overvoltage (Vpk)
400
600
600
600
Maximum Off-State Leakage Current (mA)
5
5
5
0.1
Minimum Off-State dv/dt (v/µs)
200
200
200
500
Maximum Load Current (Arms)
3
3
4
5
Minimum Load Current (Arms)
0.02
0.02
0.02
0.06
Maximum Surge Current (Apk for 16.67 mS)
90
90
130
250
Maximum On-State Voltage Drop
1.6
1.6
1.6
1.4
Minimum Power Factor @ Max. Load
0.5
0.5
0.5
0.5
Opto22
Opto22
MP120D4
MP240D4
Control Voltage (Vdc)
3 - 24
3 - 24
Typical Control Current (mA)
24
24
Load Voltage (Vrms) 47-63 Hz
12 - 140
24 - 280
Transient Overvoltage (Vpk)
600
600
Maximum Off-State Leakage Current (mA)
5
5
Maximum Load Current (Arms)
4
4
Minimum Load Current (Arms)
Maximum Surge Current (Apk for 16.67 mS)
47
47
Maximum On-State Voltage Drop
1.6
1.6
Crydom
Opto22
Opto22
MPDCD3(-B)
DC60MP
DC200MP
Control Voltage (Vdc)
3 - 32
3 - 24
3 - 24
Typical Control Current (mA)
23
24
24
Load Voltage (Vdc)
3 - 60
3 - 60
12 - 250
Maximum Load Current (Adc)
3
3
1
Minimum Load Current (Adc)
0.02
Maximum Surge Current (Adc for 1 Second)
5
5
2
Maximum On-State Voltage Drop (Vdc)
1.5
1.5
1.5
Maximum Off-State Leakage Current (mA)
1.0
1.0
1.0
Содержание RBE2-8
Страница 14: ...RBE2 8 INTRODUCTION RBE2 8 User Manual ADVANCED MICRO CONTROLS INC 14 Notes ...
Страница 30: ...PROTOCOL SPECIFIC INFORMATION RBE2 8 User Manual ADVANCED MICRO CONTROLS INC 30 Notes ...
Страница 48: ...MODBUS TCP CONFIGURATION RBE2 8 User Manual ADVANCED MICRO CONTROLS INC 48 Notes ...
Страница 54: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC ...