20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
RBE2-8 User Manual
S
ET
THE
IP A
DDRESS
AND
P
ROTOCOL
27
2.2b Use the Embedded Web Server (continued)
2.2b.3 Network Setup Page
1) Click on the [Network Setup] button to switch to the Network Setup page shown below. This page shows
the current IP address settings, as well as the configured protocol.
Figure T2.2 RBE2-8 Network Setup Web Page
2) Enter your desired values into the IP Address, Subnet Mask, and Default Gateway fields.
The Default Gateway setting is not optional! It must be set to a valid address on the chosen
subnet. Because the Default Gateway is often not used in device level networks, if you do not
have a required value for it, AMCI suggests setting the Default Gateway to the IP address of
your host controller.
3) If needed, click on the proper radio button to select the required protocol.
4) Click on the [Write Configuration] button to write the new configuration to the unit. If there are any errors
with the data, the unit will display a warning message instead of accepting the new values.